EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Consistent Quadratic Phase Formation in 3D Fast Spin Echo Using Frequency‐Modulated RF Pulses

Naoharu Kobayashi, Michael Garwood

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 666-681

DOI: 10.1002/mrm.70368 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-04-02. Written by Naoharu Kobayashi and 1 co-authors. Institution: Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA. Major MEDLINE topics: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Brain. 43 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIBIB NIH HHS, NIH HHS, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Frequency‐modulated (FM) RF pulses achieve broadband excitation with low RF peak power, which is required in MRI with inhomogeneous magnetic fields. However, the quadratic phase generated with FM pulses makes it difficult to use them in fast spin echo (FSE), because even and odd refocused echoes have different spatial phase profiles. In this article, we formulate the condition that can generate a consistent quadratic phase in the two echo components in 3D FSE using FM pulses.

Methods

The consistent quadratic phase condition in 3D FM‐FSE was formulated with the Cayley‐Klein parameters. The B 1 + ‐dependent phase in FM excitation was compensated by adjusting the initial phase of FM pulses. The consistent quadratic phase in 3D FM‐FSE and the impacts from the B 1 + ‐dependent phase were simulated with extended phase graph (EPG). The EPG simulation was validated by comparing with experimental results at 3 T. Finally, in vivo brain imaging was conducted with T 1 ‐ and T 2 ‐weighted contrasts.

Results

In EPG simulation, a consistent quadratic phase was generated in all echoes in 3D FM‐FSE under the formulated condition. The EPG simulation matched well with experimental results. The B 1 + ‐dependent phase adjustment on FM pulses improved the magnitude profile of the refocused echoes. Despite the presence of large field inhomogeneity, 3D FM‐FSE achieved in vivo brain imaging with good T 1 ‐ and T 2 ‐contrasts.

Conclusion

Achieving consistent quadratic phase in all refocused echoes in 3D FM‐FSE makes it possible to use FM pulses in the non‐adiabatic regime. 3D FM‐FSE is a promising pulse sequence for MRI in inhomogeneous magnetic fields.

Subjects

MeSH terms (MEDLINE)

Imaging, Three-DimensionalMagnetic Resonance ImagingBrainRadio WavesAlgorithmsHumansComputer SimulationPhantoms, ImagingReproducibility of Results

Author keywords

fast spin echofrequency‐modulated RF pulseinhomogeneous field MRIquadratic phase

Authors and institutions

  • Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.

Funding

  • NIBIB NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Kobayashi, N., & Garwood, M. (2026). Consistent Quadratic Phase Formation in 3D Fast Spin Echo Using Frequency‐Modulated RF Pulses. Magnetic Resonance in Medicine, 96(2), 666-681. https://doi.org/10.1002/mrm.70368

Vancouver

Kobayashi N, Garwood M. Consistent Quadratic Phase Formation in 3D Fast Spin Echo Using Frequency‐Modulated RF Pulses. Magnetic Resonance in Medicine. 2026;96(2):666-681. doi:10.1002/mrm.70368

BibTeX
@article{Kobayashi2026,
  author = {Kobayashi, Naoharu and Garwood, Michael},
  title = {Consistent Quadratic Phase Formation in 3D Fast Spin Echo Using Frequency‐Modulated RF Pulses},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {666--681},
  doi = {10.1002/mrm.70368}
}
Start for free →