EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic Mode Decomposition ( DMD ) for Low‐Latency Real‐Time Cardiac MRI

Ecrin Yagiz iD, Bilal Tasdelen iD, Ibrahim K Ozaslan, Mihailo R Jovanovic, Ye Tian iD, Krishna S Nayak iD

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 623-634

DOI: 10.1002/mrm.70360 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 30.03.2026. Verfasst von Ecrin Yagiz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, Californ…. Hauptthemen laut MEDLINE: Heart, Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Image Interpretation, Computer-Assisted. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NICHD NIH HHS, NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To demonstrate dynamic mode decomposition ( DMD ) for high spatiotemporal low‐latency online reconstruction in 2D real‐time cardiac MRI.

Methods

DMD was applied to 2D spiral balanced steady state free precession ( bSSFP ) real‐time adult and fetal cardiac MRI at 0.55 T, with data from 10 healthy adult volunteers (3F/7M; age: 21–49; BMI: 20–34) and 6 pregnant females (maternal age: 30–41; maternal BMI: 22–47; gestational age: 23 weeks 6 days–37 weeks 5 days). DMD model appropriateness was assessed against off‐line spatiotemporally constrained reconstruction ( STCR ) as the reference. We retrospectively evaluated DMD‐based low‐latency online reconstruction at two temporal resolutions (21 and 42 ms/frame). DMD modes were estimated from the most recently acquired frames and used to remove aliasing while preserving underlying physiological motion.

Results

DMD represented cardiac dynamics with normalized root‐mean‐square error ( NRMSE ) less than 7% when all modes retained. Low‐latency DMD‐based online reconstruction performed de‐aliasing while preserving the physiological motion, supporting framerates (21 and 42 ms/frame).

Conclusion

We have demonstrated that the DMD framework is applicable to 2D real‐time cardiac MRI and for low‐latency de‐aliasing for better online reconstruction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HeartMagnetic Resonance ImagingImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CineHumansFemaleAdultAlgorithmsPregnancyYoung AdultReproducibility of ResultsImage EnhancementRetrospective Studies

Stichwörter der Autor:innen

cardiac MRIdynamic mode decompositionimage reconstructioninteractive imagingonline reconstruction

Autor:innen und Institutionen

  • Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.

ORCID-Profile: Ecrin Yagiz, Bilal Tasdelen, Ye Tian, Krishna S Nayak

Förderung

  • NIH HHS
  • NICHD NIH HHS
  • NHLBI NIH HHS
  • National Institutes of Health

Zitieren

APA

Yagiz, E., Tasdelen, B., Ozaslan, I. K., Jovanovic, M. R., Tian, Y., & Nayak, K. S. (2026). Dynamic Mode Decomposition ( DMD ) for Low‐Latency Real‐Time Cardiac MRI. Magnetic Resonance in Medicine, 96(2), 623-634. https://doi.org/10.1002/mrm.70360

Vancouver

Yagiz E, Tasdelen B, Ozaslan IK, Jovanovic MR, Tian Y, Nayak KS. Dynamic Mode Decomposition ( DMD ) for Low‐Latency Real‐Time Cardiac MRI. Magnetic Resonance in Medicine. 2026;96(2):623-634. doi:10.1002/mrm.70360

BibTeX
@article{Yagiz2026,
  author = {Yagiz, Ecrin and Tasdelen, Bilal and Ozaslan, Ibrahim K and Jovanovic, Mihailo R and Tian, Ye and Nayak, Krishna S},
  title = {Dynamic Mode Decomposition ( DMD ) for Low‐Latency Real‐Time Cardiac MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {623--634},
  doi = {10.1002/mrm.70360}
}
Kostenlos starten →