EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Water/Fat Separated Echo Planar Time‐Resolved Imaging ( WFS ‐ EPTI ) for Distortion‐Free Multi‐Contrast MRI

Zhangxuan Hu, Timothy G Reese, Lawrence L Wald, Jonathan R Polimeni, Zijing Dong iD, Fuyixue Wang iD

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 580-595

DOI: 10.1002/mrm.70355 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 09.04.2026. Verfasst von Zhangxuan Hu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Adipose Tissue, Image Processing, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NINDS NIH HHS, NIA NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Echo‐planar time‐resolved imaging (EPTI) provides distortion‐ and T2/T2* blurring‐free multi‐echo/multi‐contrast imaging with fast speed, making it an efficient acquisition method for various MRI applications. Here, we aim to achieve water–fat separation for EPTI to improve fat signal removal for brain/body imaging applications. Theory and Methods A water/fat separated EPTI (WFS‐EPTI) technique is developed, which leverages the intrinsic multi‐echo data provided by EPTI readout and introduces a novel strategy for highly‐accelerated spatiotemporal encoding and reconstruction to separate water and fat signals. Specifically, DIXON encoding is integrated into the spatiotemporal acquisition by acquiring the echo train at scheduled TEs and echo‐spacing, therefore modulating the rapidly changing fat phase evolution across EPTI readout into a more uniform, coherent manner (e.g., in‐phase and out‐of‐phase conditions for odd and even image series). This enables robust subspace representations even in the presence of fat signals. A joint subspace reconstruction is then proposed, which separately performs data consistency for each echo group to ensure fidelity, while jointly leveraging shared information to improve conditioning. Furthermore, an auto‐calibrated WFS‐EPTI is developed to improve motion robustness for abdominal imaging, and a data‐driven basis extraction is employed to address imperfect in‐phase/out‐of‐phase conditions.

Results

Both phantom experiments and in vivo human imaging across multiple body regions—including brain, head–neck, and abdomen—demonstrated the feasibility of the proposed method.

Conclusion

The proposed WFS‐EPTI can provide water/fat separation in rapid acquisition and obtain high resolution, distortion‐free multi‐contrast/quantitative imaging in the presence of fat signals.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingAdipose TissueImage Processing, Computer-AssistedMagnetic Resonance ImagingHumansAlgorithmsWaterPhantoms, ImagingBrain

Stichwörter der Autor:innen

body imagingchemical shift artifactsecho‐planar imaging (EPI)fat saturationfat suppressionsubspace reconstruction

Substanzen

Water

Autor:innen und Institutionen

  • Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
  • Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA.
  • Harvard-MIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.

ORCID-Profile: Zijing Dong, Fuyixue Wang

Förderung

  • NIH HHS
  • NINDS NIH HHS
  • NIA NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Hu, Z., Reese, T. G., Wald, L. L., Polimeni, J. R., Dong, Z., & Wang, F. (2026). Water/Fat Separated Echo Planar Time‐Resolved Imaging ( WFS ‐ EPTI ) for Distortion‐Free Multi‐Contrast MRI. Magnetic Resonance in Medicine, 96(2), 580-595. https://doi.org/10.1002/mrm.70355

Vancouver

Hu Z, Reese TG, Wald LL, Polimeni JR, Dong Z, Wang F. Water/Fat Separated Echo Planar Time‐Resolved Imaging ( WFS ‐ EPTI ) for Distortion‐Free Multi‐Contrast MRI. Magnetic Resonance in Medicine. 2026;96(2):580-595. doi:10.1002/mrm.70355

BibTeX
@article{Hu2026,
  author = {Hu, Zhangxuan and Reese, Timothy G and Wald, Lawrence L and Polimeni, Jonathan R and Dong, Zijing and Wang, Fuyixue},
  title = {Water/Fat Separated Echo Planar Time‐Resolved Imaging ( WFS ‐ EPTI ) for Distortion‐Free Multi‐Contrast MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {580--595},
  doi = {10.1002/mrm.70355}
}
Kostenlos starten →