Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues
Magnetic Resonance in Medicine · 2026-07 · 96 (1) · 460-468
DOI: 10.1002/mrm.70346 ↗At a glance
Journal article in Magnetic Resonance in Medicine, published online on 2026-03-19. Written by Stefan Kuczera and 1 co-authors. Institution: Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. Major MEDLINE topics: Diffusion Magnetic Resonance Imaging, Image Enhancement, Image Interpretation, Computer-Assisted, Prostate. 13 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, Swedish Governmental Funding of Clinical Research (ALF), NCI NIH HHS.
Abstract (original language)
Purpose
Devising methodology to characterize and optimize acquisition schemes for biological tissues, such as the prostate, that produce model‐based synthetic diffusion‐weighted images and derived model parameters with predictable SNR improvement.
Methods
The averaging effect (AE) in synthetic diffusion‐weighted images obtained through fitting of various signal decay models to signals measured over 21 linearly spaced b‐values between 0 and is determined with analytic expressions. Similarly, the standard deviation of a retrospective 2‐point ADC fit based on the synthetic data is analyzed. Furthermore, acquisition schemes that achieve constant SNR or constant AE for synthetic images over the same b‐value range are devised by means of numerical optimization using either a custom iterative method or a standard function optimizer. These acquisition schemes are verified by measurements on a phantom with a non‐monoexponential diffusion signal decay combined with a bootstrapping approach to increase the number of data samples.
Results
The dependence of AE on model function and parameters is complex. Repeated measurements at specific b‐values can boost AE locally, while improvements in ADC uncertainty are particularly pronounced for repetitions of the higher b‐value. Optimization of acquisition schemes generally results in discrete b‐values, whereby the number of b‐values corresponds to the number of model parameters. Results from phantom measurements are in agreement with the theoretical predictions.
Conclusion
The presented analytical calculations and numerical optimizations can be useful to improve acquisition schemes under various experimental conditions and clinical needs.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
- Department of Radiology, Brigham Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
ORCID profiles: Stefan Kuczera, Stephan E Maier
Funding
- NIH HHS
- Swedish Governmental Funding of Clinical Research (ALF)
- NCI NIH HHS
- Cancerfonden
- Vetenskapsrådet
- Barncancerfonden
- NIBIB NIH HHS
- National Institutes of Health
Cite
APA
Kuczera, S., & Maier, S. E. (2026). Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues. Magnetic Resonance in Medicine, 96(1), 460-468. https://doi.org/10.1002/mrm.70346
Vancouver
Kuczera S, Maier SE. Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues. Magnetic Resonance in Medicine. 2026;96(1):460-468. doi:10.1002/mrm.70346
BibTeX
@article{Kuczera2026,
author = {Kuczera, Stefan and Maier, Stephan E},
title = {Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {1},
pages = {460--468},
doi = {10.1002/mrm.70346}
}