EUVIMEDObjevte EUVIMED
Open access · CC BY-NC-ND 4.0

Double Asymmetric Spin Echo EPI ( dASE ‐ EPI ) Enables fMRI of the Entire Rat Brain at 9.4 T

Kyle A Johnson iD, Hanbing Lu iD, Jason W Sidabras iD

Magnetic Resonance in Medicine · 2026-07 · 96 (1) · 366-373

DOI: 10.1002/mrm.70338 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-03-12. Written by Kyle A Johnson and 2 co-authors. Institution: Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin, USA. Major MEDLINE topics: Echo-Planar Imaging, Brain, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Cited 1 times so far (Crossref); 41 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIH HHS, National Institutes of Health.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

Development and evaluation of a double asymmetric spin echo planar imaging ( dASE ‐ EPI ) sequence to balance sensitivity to blood oxygenation level‐dependent ( BOLD ) contrast with mitigation of susceptibility‐induced intravoxel spin dephasing in ultra high‐field rodent brain imaging.

Methods

A dASE ‐ EPI pulse sequence was implemented and resting‐state BOLD fMRI was acquired in the rat brain. Data acquired with dASE ‐ EPI were compared to conventional gradient‐recalled EPI . Functional connectivity analyses were performed to assess detection of established networks and to evaluate signal recovery in regions affected by susceptibility (e.g., amygdala, hypothalamic nuclei). Results dASE ‐ EPI was found to provide BOLD sensitivity that was non‐inferior to conventional GRE ‐ EPI while substantially reducing susceptibility‐related signal loss. Established functional networks including the bilateral insular, bilateral sensory, and default mode network were reliably detected with dASE ‐ EPI . Functional connectivity of the amygdala, which was obscured in GRE ‐ EPI , was recoverable with the proposed sequence.

Conclusion

The proposed dASE ‐ EPI pulse sequence is a viable solution when studying brain regions which suffer from severe susceptibility artifacts.

Subjects

MeSH terms (MEDLINE)

Echo-Planar ImagingBrainMagnetic Resonance ImagingImage Processing, Computer-AssistedBrain MappingAnimalsRatsMaleRats, Sprague-DawleyAlgorithms

Author keywords

BOLDamygdalafunctional connectivitysusceptibility

Authors and institutions

  • Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
  • Neuroimaging Research Branch, National Institute on Drug Abuse, National Institutes of Health, Baltimore, Maryland, USA.

ORCID profiles: Kyle A Johnson, Hanbing Lu, Jason W Sidabras

Funding

  • NIH HHS
  • National Institutes of Health

Cite

APA

Johnson, K. A., Lu, H., & Sidabras, J. W. (2026). Double Asymmetric Spin Echo EPI ( dASE ‐ EPI ) Enables fMRI of the Entire Rat Brain at 9.4 T. Magnetic Resonance in Medicine, 96(1), 366-373. https://doi.org/10.1002/mrm.70338

Vancouver

Johnson KA, Lu H, Sidabras JW. Double Asymmetric Spin Echo EPI ( dASE ‐ EPI ) Enables fMRI of the Entire Rat Brain at 9.4 T. Magnetic Resonance in Medicine. 2026;96(1):366-373. doi:10.1002/mrm.70338

BibTeX
@article{Johnson2026,
  author = {Johnson, Kyle A and Lu, Hanbing and Sidabras, Jason W},
  title = {Double Asymmetric Spin Echo EPI ( dASE ‐ EPI ) Enables fMRI of the Entire Rat Brain at 9.4 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {1},
  pages = {366--373},
  doi = {10.1002/mrm.70338}
}
Start for free →