EUVIMEDEUVIMED entdecken
Open Access

Improving standardization and accuracy of in vivo omega plot exchange parameter determination using rotating‐frame model‐based fitting of quasi‐steady‐state Z‐spectra

Julius Juhyun Chung iD, Hahnsung Kim iD, Yang Ji iD, Dongshuang Lu, Iris Y Zhou iD, Phillip Zhe Sun iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30259 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Julius Juhyun Chung und 5 weiteren Autor:innen. Beteiligte Einrichtung: Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging, Algorithms. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 92 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: School of Medicine, Emory University, Emory National Primate Research Center, Emory University, NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Although Ω‐plot‐driven quantification of in vivo amide exchange properties has been demonstrated, differences in scan parameters may complicate the fidelity of determination. This work systematically evaluated the use of quasi‐steady‐state (QUASS) Z‐spectra reconstruction to standardize in vivo amide exchange quantification across acquisition conditions and further determined it in vivo.

Methods

Simulation and in vivo rodent brain chemical exchange saturation transfer (CEST) data at 4.7 T were fit with and without QUASS reconstruction using both multi‐Lorentzian and model‐based fitting approaches. pH modulation was accomplished both in simulation and in vivo by inducing global ischemia via cardiac arrest. Amide parameters were determined via Ω‐plots and compared across methods.

Results

Simulation showed that Ω‐plots using multi‐Lorentzian fitting could underestimate the exchange rate, with error increasing as conditions diverged from the steady state. In comparison, model‐based fitting using QUASS estimated the same exchange rate within 2%. These results aligned with in vivo findings where multi‐Lorentzian fitting of native Z‐spectra resulted in an exchange rate of 64 ± 13 s −1 (38 ± 16 s −1 after cardiac arrest), whereas model‐based fitting of QUASS Z‐spectra yielded an exchange rate of 126 ± 25 s −1 (49 ± 13 s −1 ).

Conclusion

The model‐based fitting of QUASS CEST Z‐spectra enables consistent and accurate quantification of exchange parameters through Ω‐plot construction by reducing error due to signal overlap and nonequilibrium CEST effects.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainMagnetic Resonance ImagingAlgorithmsAnimalsRatsComputer SimulationReproducibility of ResultsImage Processing, Computer-AssistedRats, Sprague-DawleyMale

Stichwörter der Autor:innen

Chemical exchange saturation transfer (CEST)Omega plotpHquasi‐steady‐state (QUASS)stroke

Autor:innen und Institutionen

  • Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, Georgia, USA.
  • Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA.
  • Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
  • Winship Cancer Institute, Emory University School of Medicine, Atlanta, Georgia, USA.

ORCID-Profile: Julius Juhyun Chung, Hahnsung Kim, Yang Ji, Iris Y Zhou, Phillip Zhe Sun

Förderung

  • School of Medicine, Emory University
  • Emory National Primate Research Center, Emory University
  • NINDS NIH HHS
  • NHLBI NIH HHS
  • NCATS NIH HHS
  • NIH HHS
  • Yerkes National Primate Research Center, Emory University
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Chung, J. J., Kim, H., Ji, Y., Lu, D., Zhou, I. Y., & Sun, P. Z. (2025). Improving standardization and accuracy of in vivo omega plot exchange parameter determination using rotating‐frame model‐based fitting of quasi‐steady‐state Z‐spectra. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30259

Vancouver

Chung JJ, Kim H, Ji Y, Lu D, Zhou IY, Sun PZ. Improving standardization and accuracy of in vivo omega plot exchange parameter determination using rotating‐frame model‐based fitting of quasi‐steady‐state Z‐spectra. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30259

BibTeX
@article{Chung2025,
  author = {Chung, Julius Juhyun and Kim, Hahnsung and Ji, Yang and Lu, Dongshuang and Zhou, Iris Y and Sun, Phillip Zhe},
  title = {Improving standardization and accuracy of in vivo omega plot exchange parameter determination using rotating‐frame model‐based fitting of quasi‐steady‐state Z‐spectra},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30259}
}
Kostenlos starten →