Jointly Learned 3D Non‐Cartesian Sampling With Wave Encoding and Reconstruction for Neurovascular Phase Contrast MRI
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.70215 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Chenwei Tang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain. Die Arbeit nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, NIH HHS, NIA NIH HHS.
Abstract (Originalsprache)
Purpose
To develop accelerated 3D phase contrast (PC) MRI using jointly learned wave encoding and reconstruction.
Methods
Pseudo‐fully sampled neurovascular 4D flow data ( N = 40) and a simulation framework were used to learn phase encoding locations, wave readout parameters, and model‐based reconstruction network (MoDL) for a rapid 3D PC scan (2.25 min). Parameters were also learned for an otherwise identical scan without wave encoding. Prospective scans with and without wave sampling, time‐matched 3D radial, and reference 3D radial (5.65 min) were conducted in a flow phantom and 12 healthy participants. Flow rate, pixel‐wise velocity, and variability of maximum velocity () were compared.
Results
In the phantom, learned wave scans provided accurate flow rates compared to flow probe values (0.170 ± 0.002 vs. 0.17, 0.152 ± 0.003 vs. 0.15, 1.838 ± 0.044 vs. 1.83 L/min) and showed high correlation with reference scan (slope = 0.97, R 2 = 0.99). In vivo, learned wave scans demonstrated reduced aliasing and blurring, and better small vessel conspicuity compared to scans without wave sampling and time‐matched 3D radial scans. The internal carotid artery (ICA) flow rate coefficient of variation (CV) and intraclass correlation coefficient (ICC) for learned wave scans were similar to reference 3D radial scans (CV = 6.569, ICC = 0.927; reference CV = 6.553, ICC = 0.910). Learned wave sampling demonstrated similar or lower in middle cerebral artery (MCA), basilar artery (BA), superior sagittal sinus (SSS), and most ICA segments than the longer reference scan.
Conclusion
This work demonstrates feasibility, improved image quality and accurate flow measurements of learned wave sampling and MoDL reconstruction for 3D PC MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Mechanical Engineering, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Physics, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA.
ORCID-Profile: Chenwei Tang, Brock W Jolicoeur, Caroline A Doctor, Kevin M Johnson
Förderung
- NINDS NIH HHS
- NIH HHS
- NIA NIH HHS
- National Institutes of Health
Zitieren
APA
Tang, C., Jolicoeur, B. W., Rice, J., Doctor, C. A., Yardim, Z. S., Rivera-Rivera, L. A., Eisenmenger, L. B., & Johnson, K. M. (2025). Jointly Learned 3D Non‐Cartesian Sampling With Wave Encoding and Reconstruction for Neurovascular Phase Contrast MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70215
Vancouver
Tang C, Jolicoeur BW, Rice J, Doctor CA, Yardim ZS, Rivera-Rivera LA, et al. Jointly Learned 3D Non‐Cartesian Sampling With Wave Encoding and Reconstruction for Neurovascular Phase Contrast MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.70215
BibTeX
@article{Tang2025,
author = {Tang, Chenwei and Jolicoeur, Brock W and Rice, James and Doctor, Caroline A and Yardim, Zaynab S and Rivera-Rivera, Leonardo A and Eisenmenger, Laura B and Johnson, Kevin M},
title = {Jointly Learned 3D Non‐Cartesian Sampling With Wave Encoding and Reconstruction for Neurovascular Phase Contrast MRI},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.70215}
}
EUVIMED