Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Laura J C Barendsz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Tomography. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a noninvasive method for estimating dielectric properties over a wide frequency range from 50 to 600 MHz. Existing methods are limited in accuracy and provide single‐frequency results. Furthermore, accurate knowledge of dielectric properties becomes more important, since medical device design and safety evaluation increasingly rely on computational modeling‐based evaluation.

Methods

Tissue composition assessment was performed to find the most important factors for the dielectric properties, which were sodium, potassium, and water. These were measured with a 3D acquisition‐weighted density‐adapted stack‐of‐stars scheme (Na and K) and an inversion recovery turbo spin echo sequence (H). Measurements were conducted in muscle‐representative phantoms and six healthy volunteers. These measurements were used as input for mixture models, which were used to correlate the dielectric properties of the mixture with its constituents. Four different mixture models were tested to assess the feasibility of this method.

Results

With the Maxwell–Garnett mixture model, a 7.9% error in the real relative permittivity and a 4.0% error in the effective conductivity are found for the phantoms. The in vivo values are in a similar range to those reported in literature.

Conclusion

We presented the feasibility of estimating dielectric properties over a wide frequency band with quantitative MRI, leading to a new method: HNaK‐TiCEPT. A discrepancy can be observed in the 50–200 MHz range, but the data aligns with literature from 200–600 MHz. These results show substantial intersubject differences in effective conductivity (29%), supporting the need for an accurate method to provide in vivo dielectric tissue properties.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedTomographyHumansPhantoms, ImagingSodiumAlgorithmsAdultPotassiumImaging, Three-DimensionalMaleHealthy VolunteersComputer SimulationElectric ImpedanceFemale

Stichwörter der Autor:innen

electrical conductivityelectrical properties tomography (EPT)mixture theorypermittivitypotassium MRIsodium MRItissue water content

Substanzen

SodiumPotassium

Autor:innen und Institutionen

  • Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
  • Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Department of Neurology, Medical University of Graz, Graz, Austria.
  • Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Department of Radiotherapy, Erasmus University Medical Center Cancer Institute, Rotterdam, the Netherlands.

ORCID-Profile: Laura J C Barendsz, Kemal Sumser, Teresa Gerhalter, Rob M C Mestrom, Armin M Nagel, Margarethus M Paulides

Förderung

  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek
  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Barendsz, L. J. C., Sumser, K., Gerhalter, T., Mestrom, R. M. C., Nagel, A. M., & Paulides, M. M. (2026). Ticept: Wideband Electrical Properties Tomography by Tissue Composition Assessment With Quantitative 1$$ {}^1 $$H 23$$ {}^{23} $$Na 39$$ {}^{39} $$K Multinuclear MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70139

Vancouver

Barendsz LJC, Sumser K, Gerhalter T, Mestrom RMC, Nagel AM, Paulides MM. Ticept: Wideband Electrical Properties Tomography by Tissue Composition Assessment With Quantitative 1$$ {}^1 $$H 23$$ {}^{23} $$Na 39$$ {}^{39} $$K Multinuclear MRI. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70139

BibTeX
@article{Barendsz2026,
  author = {Barendsz, Laura J C and Sumser, Kemal and Gerhalter, Teresa and Mestrom, Rob M C and Nagel, Armin M and Paulides, Margarethus M},
  title = {Ticept: Wideband Electrical Properties Tomography by Tissue Composition Assessment With Quantitative 1$$ ^1 $$H 23$$ ^23 $$Na 39$$ ^39 $$K Multinuclear MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70139}
}
Kostenlos starten →