First In Vivo 23 Na Human Imaging at 10.5 T Using a Combined Sodium‐Proton Transceiver Body Array

Simon Schmidt iD, Arcan M Ertürk, Gregory J Metzger iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70201 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Simon Schmidt and 2 co-authors. Institution: Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA. Major MEDLINE topics: Magnetic Resonance Imaging, Sodium. 49 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To demonstrate the first in vivo human 23 Na MRI at 10.5 T using a novel dual‐tuned transceiver body array and to evaluate a self‐gating approach for respiratory motion compensation, focusing on renal imaging.

Methods

A custom‐built eight‐channel 23 Na‐loop 1 H‐dipole transceiver array was designed, constructed, and characterized. Safe operation was ensured through comparison of electromagnetic simulations against B 1 + and SAR phantom measurements. A programmable motion phantom mimicked respiratory motion to assess self‐gating for both the 23 Na and 1 H acquisitions. Finally, in vivo human abdominal 23 Na and 1 H data were acquired in three healthy volunteers under free breathing, applying the self‐gating approach.

Results

The array's electromagnetic model showed good agreement with experimental data, with B 1 + NRMSE values of 0.16 for 23 Na, 0.32 for 1 H, and SAR NRMSE values of 0.35 for 23 Na and 0.22 for 1 H. Total power limits of 125 and 42 W were implemented for 23 Na and 1 H, respectively. The motion phantom study confirmed that both 23 Na and 1 H self‐gating signals accurately tracked the programmed ground truth motion (correlation coefficients: 0.979 for 23 Na, 0.995 for 1 H). Motion binning significantly improved image sharpness as quantitatively evaluated in the phantom. In vivo, self‐gating robustly captured respiratory motion and effectively enabled motion compensation, as shown in binned images with enhanced anatomical detail.

Conclusions

We successfully performed the first in vivo human 23 Na MRI at 10.5 T. The developed dual‐tuned array and validated self‐gating technique enable 10.5 T imaging in humans, paving the way for quantitative studies of sodium homeostasis and advancing diagnostic capabilities.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingSodiumHumansPhantoms, ImagingAdultEquipment DesignKidneyProtonsMaleSodium IsotopesImage Processing, Computer-Assisted

Author keywords

10.5 Tbody MRIself‐gatingsodium MRIultra‐high field MRI

Substances

SodiumProtonsSodium Isotopes

Authors and institutions

  • Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.
  • Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.

ORCID profiles: Simon Schmidt, Gregory J Metzger

Funding

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Cite

APA

Schmidt, S., Ertürk, A. M., & Metzger, G. J. (2026). First In Vivo 23 Na Human Imaging at 10.5 T Using a Combined Sodium‐Proton Transceiver Body Array. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70201

Vancouver

Schmidt S, Ertürk AM, Metzger GJ. First In Vivo 23 Na Human Imaging at 10.5 T Using a Combined Sodium‐Proton Transceiver Body Array. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70201

BibTeX
@article{Schmidt2026,
  author = {Schmidt, Simon and Ertürk, Arcan M and Metzger, Gregory J},
  title = {First In Vivo 23 Na Human Imaging at 10.5 T Using a Combined Sodium‐Proton Transceiver Body Array},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70201}
}