EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comprehensive 4D Parallel Transmission Spatial‐Spectral Pulse Design for Slab‐Selective Uniform Water‐Selective Excitation: Demonstration in the Human Brain at 7 Tesla

Xin Shao iD, Zhe Zhang, Wen Zhong, Hua Guo iD, Kamil Ugurbil iD, Xiaoping Wu iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70183 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Xin Shao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Imaging, Three-Dimensional, Image Processing, Computer-Assisted. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NIBIB NIH HHS, NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To propose a new parallel transmission (pTx) spatial‐spectral (SPSP) pulse design for achieving slab‐selective uniform water‐selective excitation without unwanted out‐of‐slab fat excitation when using bipolar slab‐selective gradients to maintain a sharp slab profile.

Methods

Our new pTx SPSP pulses were designed by formulating the design problem comprehensively in the 4D space (1D spectral and 3D spatial domains) and by incorporating a SPINS‐like 2D excitation k‐space trajectory for within‐slab flip‐angle homogenization. Our new design was validated at 7 T using simulation, phantom and human experiments with the commercial Nova eight‐channel transmit RF head coil. Its utility was demonstrated by comparing to traditional multi‐spoke pTx SPSP pulses.

Results

In both simulation and experiments, our design outperformed traditional approaches, producing slab‐selective uniform water‐selective excitation with no out‐of‐slab fat excitation. Quantitatively, coefficient of variation measuring excitation non‐uniformity reduced by up to ∼23%.

Conclusion

Our proposed new design provides an effective solution for slab‐selective uniform water‐selective excitation, holding a promise to many applications including mesoscale BOLD fMRI and fat‐free body imaging at ultrahigh field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainImaging, Three-DimensionalImage Processing, Computer-AssistedHumansPhantoms, ImagingWaterAlgorithmsComputer SimulationReproducibility of Results

Stichwörter der Autor:innen

parallel transmissionradiofrequency pulse designslab‐selective excitationspatial‐spectral pulse designwater‐selective excitation

Substanzen

Water

Autor:innen und Institutionen

  • Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
  • Tiantan Neuroimaging Center of Excellence, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
  • Center for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA.

ORCID-Profile: Xin Shao, Hua Guo, Kamil Ugurbil, Xiaoping Wu

Förderung

  • NIH HHS
  • NIBIB NIH HHS
  • NINDS NIH HHS
  • National Institutes of Health

Zitieren

APA

Shao, X., Zhang, Z., Zhong, W., Guo, H., Ugurbil, K., & Wu, X. (2026). Comprehensive 4D Parallel Transmission Spatial‐Spectral Pulse Design for Slab‐Selective Uniform Water‐Selective Excitation: Demonstration in the Human Brain at 7 Tesla. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70183

Vancouver

Shao X, Zhang Z, Zhong W, Guo H, Ugurbil K, Wu X. Comprehensive 4D Parallel Transmission Spatial‐Spectral Pulse Design for Slab‐Selective Uniform Water‐Selective Excitation: Demonstration in the Human Brain at 7 Tesla. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70183

BibTeX
@article{Shao2026,
  author = {Shao, Xin and Zhang, Zhe and Zhong, Wen and Guo, Hua and Ugurbil, Kamil and Wu, Xiaoping},
  title = {Comprehensive 4D Parallel Transmission Spatial‐Spectral Pulse Design for Slab‐Selective Uniform Water‐Selective Excitation: Demonstration in the Human Brain at 7 Tesla},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70183}
}
Kostenlos starten →