Automatic Respiratory and Bulk Patient Motion Corrected 3D Fetal MRI
Magnetic Resonance in Medicine · 2026-04 · 95 (4) · 1972-1985
DOI: 10.1002/mrm.70166 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 04.11.2025. Verfasst von Robin Ferincz und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Prenatal Diagnosis, Artifacts. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.
Abstract (Originalsprache)
Purpose
To develop a framework (ACROBATIC) for correcting motion in 3D radial fetal MRI.
Methods
Data were simulated ( N = 200) and acquired in utero ( N = 11, gestational age: 32 ± 2 weeks). Motion due to maternal respiration was estimated by extracting a self‐gating signal and applying focused navigation. Bulk motion was estimated by splitting the acquisition into sequential bins, reconstructing 3D volumes and applying rigid image registration. These combined motion estimates were used to correct k‐space. Self‐gating signals were compared to ground truth in simulations and an external sensor in utero. The cumulative position error (CPE) measured the accuracy of motion estimations relative to ground truth in simulations and relative sharpness measured the corresponding impact on image quality for both simulations and in utero data. An expert reviewer performed a blinded ranking of in utero images including uncorrected and corrected data.
Results
Self‐gating signals correlated strongly with ground truth for simulations ( R = 0.97 ± 0.01) and a external sensor for in utero data ( R = 0.75 ± 0.23). CPE decreased significantly using ACROBATIC (uncorrected: 13.33[12.73–14.05], corrected: 2.20[1.80–2.61]). Relative image sharpness increased with ACROBATIC for both simulated (4.51[2.89–5.79]) and in utero data (1.12[0.77–1.44]) consistent with expert ranking where ACROBATIC images were given the best rank in the majority of cases.
Conclusion
ACROBATIC enables motion correction in 3D radial fetal MRI. Correction of displacement due to maternal respiration and bulk motion results in improved image quality in simulations and in utero. Comparison to 2D frameworks are now warranted to establish the added diagnostic value of this approach.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- Advanced Cardiothoracic Imaging Unit, Department of Imaging, Bambino Gesù Children's Hospital IRCCS, Rome, Italy.
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, Pessac, France.
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.
- Scientific Collaborations and Strategic Partnerships, Siemens Healthcare Srl, Milano, Italy.
ORCID-Profile: Robin Ferincz, Aurélien Bustin, Davide Piccini, Milan Prša
Förderung
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Zitieren
APA
Ferincz, R., Alamo, L., Secinaro, A., Tenisch, E., Bustin, A., Piccini, D., Prša, M., Yerly, J., & Roy, C. W. (2026). Automatic Respiratory and Bulk Patient Motion Corrected 3D Fetal MRI. Magnetic Resonance in Medicine, 95(4), 1972-1985. https://doi.org/10.1002/mrm.70166
Vancouver
Ferincz R, Alamo L, Secinaro A, Tenisch E, Bustin A, Piccini D, et al. Automatic Respiratory and Bulk Patient Motion Corrected 3D Fetal MRI. Magnetic Resonance in Medicine. 2026;95(4):1972-1985. doi:10.1002/mrm.70166
BibTeX
@article{Ferincz2026,
author = {Ferincz, Robin and Alamo, Leonor and Secinaro, Aurelio and Tenisch, Estelle and Bustin, Aurélien and Piccini, Davide and Prša, Milan and Yerly, Jérôme and Roy, Christopher W},
title = {Automatic Respiratory and Bulk Patient Motion Corrected 3D Fetal MRI},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {95},
number = {4},
pages = {1972--1985},
doi = {10.1002/mrm.70166}
}