Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative study
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70100 ↗At a glance
Vergleichsstudie in Magnetic Resonance in Medicine, 2026. Written by Michael Carl and 5 co-authors. Institution: GE Healthcare, San Diego, California, USA. Major MEDLINE topics: Lung, Magnetic Resonance Imaging, Imaging, Three-Dimensional. Cited 3 times so far (Crossref); 42 references. The full text is freely available in PubMed Central. Funded by: NIAMS NIH HHS, Veterans Affairs Clinical Science Research and Development, CSRD VA.
Abstract (original language)
Purpose
To optimize and compare the performance of 3D UTE and zero echo time (ZTE) MRI sequences for high‐resolution lung imaging at 3 T.
Methods
UTE and ZTE sequences were optimized for lung imaging through phantom studies, and in vivo experiments. Imaging parameters, including bandwidth (BW) and flip angle (FA), were systematically assessed to identify the optimal settings for both sequences. A novel transient UTE sequence was introduced to enhance the SNR by allowing magnetization recovery during the respiratory wait period. Numerical simulations and in vivo experiments were conducted to compare the SNR performance of the proposed transient UTE with conventional steady‐state UTE.
Results
UTE imaging with a BW of ±125 kHz and an FA of 2° produced the sharpest lung images without noticeable artifacts. In contrast, ZTE imaging was optimal at a lower BW of ±62.5 kHz and an FA of 2°, but showed greater blurriness and more pronounced inhomogeneous excitation artifacts than UTE. The transient UTE sequence increased lung imaging SNR by approximately 11% to 20% compared to steady‐state UTE without introducing obvious artifacts.
Conclusion
UTE outperformed ZTE in terms of image sharpness and artifact reduction for lung imaging. The proposed transient UTE sequence further enhanced SNR, demonstrating the potential for improved lung MRI quality and diagnostic accuracy.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- GE Healthcare, San Diego, California, USA.
- Department of Radiology, University of California San Diego, San Diego, California, USA.
- Radiology Service, VA San Diego Healthcare System, San Diego, California, USA.
- Department of Bioengineering, University of California San Diego, San Diego, California, USA.
Funding
- NIAMS NIH HHS
- Veterans Affairs Clinical Science Research and Development
- CSRD VA
- GE Healthcare
- NIH HHS
- NIA NIH HHS
- National Institutes of Health
Cite
APA
Carl, M., Wang, J., Lo, J., Chung, J. H., Du, J., & Ma, Y. (2026). Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70100
Vancouver
Carl M, Wang J, Lo J, Chung JH, Du J, Ma Y. Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative study. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70100
BibTeX
@article{Carl2026,
author = {Carl, Michael and Wang, Jiaji and Lo, James and Chung, Jonathan H and Du, Jiang and Ma, Yajun},
title = {Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative study},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70100}
}
EUVIMED