EUVIMEDOpdag EUVIMED
VergleichsstudieOpen access

Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative study

Michael Carl, Jiaji Wang, James Lo iD, Jonathan H Chung, Jiang Du, Yajun Ma iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70100 ↗

At a glance

Vergleichsstudie in Magnetic Resonance in Medicine, 2026. Written by Michael Carl and 5 co-authors. Institution: GE Healthcare, San Diego, California, USA. Major MEDLINE topics: Lung, Magnetic Resonance Imaging, Imaging, Three-Dimensional. Cited 3 times so far (Crossref); 42 references. The full text is freely available in PubMed Central. Funded by: NIAMS NIH HHS, Veterans Affairs Clinical Science Research and Development, CSRD VA.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To optimize and compare the performance of 3D UTE and zero echo time (ZTE) MRI sequences for high‐resolution lung imaging at 3 T.

Methods

UTE and ZTE sequences were optimized for lung imaging through phantom studies, and in vivo experiments. Imaging parameters, including bandwidth (BW) and flip angle (FA), were systematically assessed to identify the optimal settings for both sequences. A novel transient UTE sequence was introduced to enhance the SNR by allowing magnetization recovery during the respiratory wait period. Numerical simulations and in vivo experiments were conducted to compare the SNR performance of the proposed transient UTE with conventional steady‐state UTE.

Results

UTE imaging with a BW of ±125 kHz and an FA of 2° produced the sharpest lung images without noticeable artifacts. In contrast, ZTE imaging was optimal at a lower BW of ±62.5 kHz and an FA of 2°, but showed greater blurriness and more pronounced inhomogeneous excitation artifacts than UTE. The transient UTE sequence increased lung imaging SNR by approximately 11% to 20% compared to steady‐state UTE without introducing obvious artifacts.

Conclusion

UTE outperformed ZTE in terms of image sharpness and artifact reduction for lung imaging. The proposed transient UTE sequence further enhanced SNR, demonstrating the potential for improved lung MRI quality and diagnostic accuracy.

Subjects

MeSH terms (MEDLINE)

LungMagnetic Resonance ImagingImaging, Three-DimensionalPhantoms, ImagingArtifactsSignal-To-Noise RatioHumansAlgorithmsAnimalsImage Processing, Computer-AssistedComputer SimulationReproducibility of Results

Author keywords

UTEZTElungsteady‐statetransient

Authors and institutions

  • GE Healthcare, San Diego, California, USA.
  • Department of Radiology, University of California San Diego, San Diego, California, USA.
  • Radiology Service, VA San Diego Healthcare System, San Diego, California, USA.
  • Department of Bioengineering, University of California San Diego, San Diego, California, USA.

ORCID profiles: James Lo, Yajun Ma

Funding

  • NIAMS NIH HHS
  • Veterans Affairs Clinical Science Research and Development
  • CSRD VA
  • GE Healthcare
  • NIH HHS
  • NIA NIH HHS
  • National Institutes of Health

Cite

APA

Carl, M., Wang, J., Lo, J., Chung, J. H., Du, J., & Ma, Y. (2026). Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70100

Vancouver

Carl M, Wang J, Lo J, Chung JH, Du J, Ma Y. Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative study. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70100

BibTeX
@article{Carl2026,
  author = {Carl, Michael and Wang, Jiaji and Lo, James and Chung, Jonathan H and Du, Jiang and Ma, Yajun},
  title = {Optimized 3D UTE and ZTE MRI for high‐resolution lung imaging: A comparative study},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70100}
}
Start for free →