Radial Hadamard-encoded 19F-MRI
Magnetic Resonance Materials in Physics, Biology and Medicine · 2025
DOI: 10.1007/s10334-025-01254-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2025. Verfasst von Kian Tadjalli Mehr und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University Medical Center Freiburg, Universi…. Hauptthemen laut MEDLINE: Fluorine-19 Magnetic Resonance Imaging, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Deutsche Herzstiftung, Berta Ottenstein Program.
Abstract (Originalsprache)
Objectives
Developing a 19 F imaging method to acquire images of the molecular inflammation tracer perfluorooctyl bromide (PFOB) without chemical shift artifacts. Materials and methods PFOB is a molecular tracer that can be used to track the response of myeloid cells. However, imaging of PFOB with 19 F-MRI is challenging due to its complex spectrum which leads to unwanted chemical shift artifacts. Spectral HE allows for separate reconstructions of each peak of the PFOB spectrum, which was combined into a single image after resonance shift correction. In this work, a Hadamard-encoded (HE) radial 3D UTE sequence was tested in phantoms and in vivo in a pig, measuring the 19 F signal in the spleen at different times after injection.
Results
Chemical shift artifacts were effectively suppressed with HE, and an SNR > 100 was observed for the 19 F signal in the spleen 2 days after injection. The signal decreased over time, and 7 days after injection it was reduced by 30%.
Discussion
Chemical shift artifact correction using HE allowed for in vivo 19 F PFOB imaging of labeled monocytes with a high SNR. Compared to spectrally selective excitation, HE increased the PFOB 19 F-MRI signal by 10%, and the simple HE-algorithm could be directly integrated into the image reconstruction of the MRI system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University Medical Center Freiburg, University of Freiburg, Killianstr. 5a, 79106, Freiburg, Germany. kian.tadjall…
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University Medical Center Freiburg, University of Freiburg, Killianstr. 5a, 79106, Freiburg, Germany.
- Department of Cardiology, Faculty of Medicine, University Medical Center Freiburg, University of Freiburg, Freiburg, Germany.
Förderung
- Deutsche Forschungsgemeinschaft
- Deutsche Herzstiftung
- Berta Ottenstein Program
- Universitätsklinikum Freiburg
Zitieren
APA
Tadjalli Mehr, K., Fischer, J., Spreter, F., Reiss, S., Boll, D., Özen, A. C., Gunashekar, D., von Zur Mühlen, C., Maier, A., & Bock, M. (2025). Radial Hadamard-encoded 19F-MRI. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-025-01254-2
Vancouver
Tadjalli Mehr K, Fischer J, Spreter F, Reiss S, Boll D, Özen AC, et al. Radial Hadamard-encoded 19F-MRI. Magnetic Resonance Materials in Physics, Biology and Medicine. 2025. doi:10.1007/s10334-025-01254-2
BibTeX
@article{TadjalliMehr2025,
author = {Tadjalli Mehr, Kian and Fischer, Johannes and Spreter, Felix and Reiss, Simon and Boll, David and Özen, Ali Caglar and Gunashekar, Deepa and von Zur Mühlen, Constantin and Maier, Alexander and Bock, Michael},
title = {Radial Hadamard-encoded 19F-MRI},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2025},
doi = {10.1007/s10334-025-01254-2}
}
EUVIMED