EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Mimicking focused ultrasound with a loop coil in acoustic radiation force imaging

Kristen Zarcone iD, Anuj Sharma iD, William A Grissom iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.70014 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2025. Written by Kristen Zarcone and 2 co-authors. Institution: Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA. Major MEDLINE topics: Elasticity Imaging Techniques, Magnetic Resonance Imaging. 23 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIMH NIH HHS, NINDS NIH HHS, NIH HHS.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

To enable development of MR‐acoustic radiation force imaging (MR‐ARFI) methods for targeting ultrasound in human subjects without the regulatory, acoustic, or hardware challenges associated with actual transcranial ultrasound setups.

Methods

MR‐ARFI is a phase‐contrast imaging method that measures focal tissue displacement produced by an ultrasound transducer, when the transducer is pulsed simultaneously with a motion encoding gradient. The ultrasound‐induced focal phase shift can be mimicked with a small loop coil that is driven by a DC pulse to produce a resonance frequency offset at the same time as the ultrasound pulse in an MR‐ARFI pulse sequence. A coil was designed and built for use in MR‐ARFI. Its focus size was characterized, its field map was measured, and volunteer experiments were performed to demonstrate its function in transcranial phase‐contrast and magnetization‐prepared MR‐ARFI.

Results

Off‐resonance field maps measured with the constructed loop coil were within 0.87% of simulations in a slice 15 mm from the coil's surface. Its “focus” further had a full‐width‐at‐half‐maximum of 22.9 mm in simulation versus 22.7 mm in the field map. In vivo results showed that the same coil driven with 13.7 mA current produced a phase shift corresponding to a realistic effective displacement of 3.5 m in a slice 19 mm from the coil in MR‐ARFI.

Conclusion

A pulsed DC loop coil can mimic ARF‐induced displacements in vivo, facilitating development of MR‐ARFI methods in vivo.

Subjects

MeSH terms (MEDLINE)

Elasticity Imaging TechniquesMagnetic Resonance ImagingHumansPhantoms, ImagingEquipment DesignTransducersBrainUltrasonographyComputer SimulationImage Processing, Computer-Assisted

Author keywords

MR‐ARFIfocused‐ultrasound

Authors and institutions

  • Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.

ORCID profiles: Kristen Zarcone, Anuj Sharma, William A Grissom

Funding

  • NIMH NIH HHS
  • NINDS NIH HHS
  • NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Cite

APA

Zarcone, K., Sharma, A., & Grissom, W. A. (2025). Mimicking focused ultrasound with a loop coil in acoustic radiation force imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70014

Vancouver

Zarcone K, Sharma A, Grissom WA. Mimicking focused ultrasound with a loop coil in acoustic radiation force imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.70014

BibTeX
@article{Zarcone2025,
  author = {Zarcone, Kristen and Sharma, Anuj and Grissom, William A},
  title = {Mimicking focused ultrasound with a loop coil in acoustic radiation force imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.70014}
}
Start for free →