EUVIMEDEUVIMED entdecken
Crossref

Wearable Ultrasound Imaging Device for Dynamic Dual-Direction Shear Wave Elastography of Shoulder Muscle

Hung-Jui Chen, Hao-Chun Chuang, Guo-Xuan Xu, Chien Chen, Wei-Ren Su, Chih-Chung Huang

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024

DOI: 10.1109/tuffc.2023.3348472 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Hung-Jui Chen und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Phantoms, Imaging, Shoulder, Wearable Electronic Devices. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: National Health Research Institutes in Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The shoulder is the most mobile joint in the human body, thus requiring intricate coordination of adjacent muscles. Patients suffered from rotator cuff muscle injuries have several typical symptoms including shoulder pain and difficulty raising the arm, thus reducing work efficiency and compromising the quality of life. Ultrasound has been used widely for shoulder soft tissue imaging as well as ultrasound elastography was introduced in shoulder examination for the dilemma of treating degenerative rotator cuff tears. However, most of the ultrasound examination was performed under a static condition. Providing dynamic information from shoulder muscle is important in clinical applications because the pains sometimes come from various positions of the shoulder during moving. In this study, a customized wearable T-shaped ultrasound transducer (128 + 128 elements) was proposed for shoulder dual-direction shear wave elastography (DDSWE), which provides the SWE for both longitudinal (SW along the muscle fiber) and transverse (SW cross the muscle fiber) directions dynamically. An optical tracking system was synchronized with an ultrasound imaging system to capture shoulder movements in 3-D space with their corresponding ultrasound images. The performance of DDSWE and the accuracy of optical tracking were verified by phantom experiments. Human studies were carried out by volunteers as they are moving their arms. The experimental results show that the bias and precision for the proposed DDSWE in elastic phantom were about 6% and 1.2% for both directions, respectively. A high accuracy of optical tracking was observed using a 3-D motor stage experimental setup. Human experiments show that the shear wave velocities (SWVs) were increased with the angles of shoulder abduction, and the average transverse and longitudinal SWVs were increased from 2.24 to 3.35 m/s and 2.95 to 5.95 m/s with abduction angle from 0° to 60°, respectively, which they are anisotropic-dependent. All the experimental results indicate that the proposed wearable ultrasound DDSWE can quantify the mechanical properties of shoulder muscles dynamically, thereby helping surgeons and physical therapists determine whether the intensity of rehabilitation shoulder be tuned down or escalated in the future.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesPhantoms, ImagingShoulderWearable Electronic DevicesEquipment DesignHumansAdultMaleMuscle, SkeletalRotator CuffTransducers

Förderung

  • National Health Research Institutes in Taiwan

Zitieren

APA

Chen, H. J., Chuang, H. C., Xu, G. X., Chen, C., Su, W. R., & Huang, C. C. (2024). Wearable Ultrasound Imaging Device for Dynamic Dual-Direction Shear Wave Elastography of Shoulder Muscle. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2023.3348472

Vancouver

Chen HJ, Chuang HC, Xu GX, Chen C, Su WR, Huang CC. Wearable Ultrasound Imaging Device for Dynamic Dual-Direction Shear Wave Elastography of Shoulder Muscle. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2023.3348472

BibTeX
@article{Chen2024,
  author = {Chen, Hung-Jui and Chuang, Hao-Chun and Xu, Guo-Xuan and Chen, Chien and Su, Wei-Ren and Huang, Chih-Chung},
  title = {Wearable Ultrasound Imaging Device for Dynamic Dual-Direction Shear Wave Elastography of Shoulder Muscle},
  journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2024},
  doi = {10.1109/tuffc.2023.3348472}
}
Kostenlos starten →