Simultaneous liver T 1 , T 2 , and ADC MR fingerprinting using optimized motion‐compensated diffusion preparations: An initial validation on volunteers
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30622 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by C Velasco and 7 co-authors. Institution: School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Major MEDLINE topics: Liver, Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Cited 4 times so far (Crossref); 82 references. The full text is freely available (open access, CC BY 4.0). Funded by: EPSRC, King's BHF Centre for Award Excellence RE, BHF Program Grant.
Abstract (original language)
Purpose
To develop a novel MR fingerprinting sequence using optimized motion‐compensated diffusion preparations for simultaneous T 1 , T 2 , and ADC quantification of liver tissue in a single breath‐held scan.
Methods
A radial spoiled gradient echo acquisition with magnetization preparation modules for T 1 , T 2, and ADC encoding is proposed. To compensate for the signal voids generated by the diffusion preparation, the combination of (1) a breath‐held scan, (2) peripheral pulse signal triggering, and (3) an optimized motion‐compensated diffusion‐preparation module is employed. Phantom experiments were performed to test the accuracy of the technique. The sequence was evaluated in 11 healthy subjects in comparison to conventional mapping techniques. Additional in vivo repeatability assessment experiments were performed.
Results
T 1 , T 2 , and ADC quantification showed good correlation (r 2 > 0.9 for all cases) with reference maps in phantoms and good agreement in vivo against clinical scans (bias not significantly different from zero). A peripheral pulse trigger delay of 200 ms was used to reduce cardiovascular motion artifacts. The repeatability tests prove a low interscan coefficient of variation and a high intraclass correlation coefficient of greater than 0.9 for all cases.
Conclusions
Simultaneous quantification of T 1 , T 2 , and ADC in liver tissue in a single MR fingerprinting scan of ˜16 s has been proposed, enabling a comprehensive evaluation of hepatic disease through co‐registered multiparametric imaging. Further studies are warranted to test this approach in patients with suspected diffuse liver disease to evaluate its potential for liver tissue characterization and tumor staging.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
- Millenium Institute for Intelligent Healthcare Engineering, Santiago, Chile.
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
- School of Engineering, Electrical Engineering Department, Pontificia Universidad Católica de Chile, Santiago, Chile.
ORCID profiles: C Velasco, P Irarrazaval
Funding
- EPSRC
- King's BHF Centre for Award Excellence RE
- BHF Program Grant
- ANID FONDECYT
- Wellcome Trust
- Millenium Institute iHEALTH
- Technical University of Munich -- Institute for Advanced Study
- Wellcome EPSRC Centre for Medical Engineering
Cite
APA
Velasco, C., Castillo-Passi, C., Chaher, N., Karampinos, D. C., Irarrazaval, P., Phinikaridou, A., Botnar, R. M., & Prieto, C. (2025). Simultaneous liver T 1 , T 2 , and ADC MR fingerprinting using optimized motion‐compensated diffusion preparations: An initial validation on volunteers. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30622
Vancouver
Velasco C, Castillo-Passi C, Chaher N, Karampinos DC, Irarrazaval P, Phinikaridou A, et al. Simultaneous liver T 1 , T 2 , and ADC MR fingerprinting using optimized motion‐compensated diffusion preparations: An initial validation on volunteers. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30622
BibTeX
@article{Velasco2025,
author = {Velasco, C and Castillo-Passi, C and Chaher, N and Karampinos, D C and Irarrazaval, P and Phinikaridou, A and Botnar, R M and Prieto, C},
title = {Simultaneous liver T 1 , T 2 , and ADC MR fingerprinting using optimized motion‐compensated diffusion preparations: An initial validation on volunteers},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30622}
}
EUVIMED