Rapid, high‐resolution and distortion‐free R2∗ mapping of fetal brain using multi‐echo radial FLASH and model‐based reconstruction
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30604 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Xiaoqing Wang and 9 co-authors. Institution: Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts. Major MEDLINE topics: Brain, Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Fetus. 70 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, NINDS NIH HHS, National Institutes of Health (NIH).
Abstract (original language)
Purpose
To develop a rapid, high‐resolution, and distortion‐free technique for simultaneous water‐fat separation, and mapping of the fetal brain at 3 T.
Methods
A 2D multi‐echo radial FLASH sequence with blip gradients is adapted for data acquisition during maternal free breathing. A calibrationless model‐based reconstruction with sparsity constraints is developed to jointly estimate water, fat, and field maps directly from k‐space. This approach was validated and compared to reference methods using numerical and NIST phantoms and data from nine fetuses between 26 and 36 weeks of gestation age.
Results
Both numerical and experimental phantom studies confirm good accuracy and precision. In fetal studies, model‐based reconstruction yields quantitative values in close agreement with those from a parallel imaging compressed sensing (PICS) technique using Graph Cut (intra‐class correlation coefficient [ICC] = 0.9601), while providing enhanced image detail. Repeated scans confirm good reproducibility (ICC = 0.9213). Compared to multi‐echo EPI, the proposed radial technique produces higher‐resolution (1.1 1.1 3 mm vs. 2–3 2–3 3 mm) maps with reduced distortion. Despite differences in motion, resolution, and distortion, values are comparable between the two acquisition strategies (ICC = 0.8049). Additionally, the proposed approach enables the synthesis of high‐resolution and distortion‐free ‐weighted images.
Conclusion
This study demonstrates the feasibility of using multi‐echo radial FLASH combined with calibrationless model‐based reconstruction for motion‐robust, distortion‐free mapping of the fetal brain at 3T, achieving a nominal resolution of mm within 2 s per slice.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
- Siemens Medical Solutions, Boston, Massachusetts.
- Department of Radiology, University of Michigan, Ann Arbor, Michigan.
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria.
- Department of Radiological Sciences, University of California Irvine, Irvine, California.
- Department of Electrical Engineering and Computer Science, University of California Irvine, Irvine, California.
ORCID profiles: Xiaoqing Wang, Zhengguo Tan, Serge Vasylechko, Onur Afacan, Martin Uecker, Simon K Warfield, Ali Gholipour
Funding
- NIBIB NIH HHS
- NINDS NIH HHS
- National Institutes of Health (NIH)
- NIH HHS
- NICHD NIH HHS
- NLM NIH HHS
Cite
APA
Wang, X., Fan, H., Tan, Z., Vasylechko, S., Yang, E., Didier, R., Afacan, O., Uecker, M., Warfield, S. K., & Gholipour, A. (2025). Rapid, high‐resolution and distortion‐free R2∗ mapping of fetal brain using multi‐echo radial FLASH and model‐based reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30604
Vancouver
Wang X, Fan H, Tan Z, Vasylechko S, Yang E, Didier R, et al. Rapid, high‐resolution and distortion‐free R2∗ mapping of fetal brain using multi‐echo radial FLASH and model‐based reconstruction. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30604
BibTeX
@article{Wang2025,
author = {Wang, Xiaoqing and Fan, Hongli and Tan, Zhengguo and Vasylechko, Serge and Yang, Edward and Didier, Ryne and Afacan, Onur and Uecker, Martin and Warfield, Simon K and Gholipour, Ali},
title = {Rapid, high‐resolution and distortion‐free R2∗ mapping of fetal brain using multi‐echo radial FLASH and model‐based reconstruction},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30604}
}
EUVIMED