Individually optimized dynamic parallel transmit pulses for 3D high‐resolution SPACE imaging at 7T
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30565 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Gian Franco Piredda und 14 weiteren Autor:innen. Beteiligte Einrichtung: Swiss Innovation Hub, Siemens Healthineers International AG, Lausanne, Switzerland. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Imaging, Three-Dimensional. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: German Federal Ministry of Education and Research Integrated Deep Learning at 7T - IDL@7T.
Abstract (Originalsprache)
Purpose
Although clinical 7T MRI offers various advantages compared to lower field strengths, achieving spatially uniform flip angle distributions remains a challenge. Sampling Perfection with Application optimized Contrast using different flip angle Evolution (SPACE) sequences employing a long train of refocusing pulses with varying flip angles pose a particular challenge in that regard. In this study, we investigate scalable dynamic parallel transmission (pTx) pulses to achieve homogeneous 3D high‐resolution SPACE brain imaging at 7T.
Methods
Non‐parametrized and scalable dynamic pTx pulses were designed for excitation, refocusing and inversion in SPACE sequences by using fast online customization (FOCUS). First, a database of B 0 and multi‐channel maps were used for optimizing universal pulses and parameters for flip angle homogeneity under strict specific absorption rate (SAR) constraints. During each new examination, B 0 and maps were acquired as additional calibration step and pTx pulses were tailored to the subject. For scalability, a symmetry condition was enforced. T 1 , T 2 , fluid‐attenuated inversion recovery (FLAIR) and double inversion recovery (DIR) SPACE images were acquired in five healthy subjects at 7T using the proposed FOCUS pulses and conventional circularly polarized (CP) pulses for comparison.
Results
Improved SNR and better image homogeneity were observed in every image acquired with FOCUS pulses in comparison to CP. Quantitative analysis showed a significant reduction in the coefficient of variation (COV) of image intensities in the cerebellum, a region notably affected by inhomogeneities across all contrasts. FLAIR images, for example, exhibited a 46% COV reduction.
Conclusion
Individually optimized dynamic pTx pulses for 3D high‐resolution SPACE imaging delivered clinically acceptable image homogeneity, enabling the application of widely used clinical contrasts at 7T.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Swiss Innovation Hub, Siemens Healthineers International AG, Lausanne, Switzerland.
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Lausanne, Switzerland.
- CIBM Center for Biomedical Imaging, Geneva, Switzerland.
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- LTS5, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
- Siemens Healthineers AG, Erlangen, Germany.
ORCID-Profile: Gian Franco Piredda, Patrick A Liebig, Tom Hilbert, Jürgen Herrler
Förderung
- German Federal Ministry of Education and Research Integrated Deep Learning at 7T - IDL@7T
Zitieren
APA
Piredda, G. F., Sleight, E., Yu, T., Klauser, A., Pato Montemayor, N., Philippe, J., Bacha, L., Di Noto, T., Maréchal, B., Liebig, P. A., Nickel, D., Kober, T., Hilbert, T., Heidemann, R. M., & Herrler, J. (2025). Individually optimized dynamic parallel transmit pulses for 3D high‐resolution SPACE imaging at 7T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30565
Vancouver
Piredda GF, Sleight E, Yu T, Klauser A, Pato Montemayor N, Philippe J, et al. Individually optimized dynamic parallel transmit pulses for 3D high‐resolution SPACE imaging at 7T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30565
BibTeX
@article{Piredda2025,
author = {Piredda, Gian Franco and Sleight, Emilie and Yu, Thomas and Klauser, Antoine and Pato Montemayor, Natalia and Philippe, Jocelyn and Bacha, Lina and Di Noto, Tommaso and Maréchal, Bénédicte and Liebig, Patrick A and Nickel, Dominik and Kober, Tobias and Hilbert, Tom and Heidemann, Robin M and Herrler, Jürgen},
title = {Individually optimized dynamic parallel transmit pulses for 3D high‐resolution SPACE imaging at 7T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30565}
}
EUVIMED