EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

CEST MRI data analysis using Kolmogorov‐Arnold network ( KAN ) and Lorentzian ‐ KAN ( LKAN ) models

Jiawen Wang, Pei Cai, Ziyan Wang, Huabin Zhang iD, Jianpan Huang iD

Magnetic Resonance in Medicine · 2025-09 · 94 (3) · 1301-1317

DOI: 10.1002/mrm.30548 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 04.06.2025. Verfasst von Jiawen Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Advanced Imaging in Medicine (AIM), Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, H…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China, University of Hong Kong.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the potential of using Kolmogorov‐Arnold Network (KAN) and propose Lorentzian‐KAN (LKAN) for CEST MRI data analysis (CEST‐KAN/CEST‐LKAN).

Methods

CEST MRI data acquired from 27 healthy volunteers at 3 T were used in this study. Data from 25 subjects were used for training and validation (548 865 Z‐spectra), whereas the remaining two were reserved for testing (51 977 Z‐spectra). The performance of multi‐layer perceptron (MLP), KAN, and LKAN models was evaluated and compared to conventional multi‐pool Lorentzian fitting (MPLF) method in generating ΔB 0 , water, and multiple CEST contrasts, including amide, relayed nuclear Overhauser effect (rNOE), and magnetization transfer (MT).

Results

The KAN and LKAN showed higher accuracy in predicting CEST parameters compared to MLP, with average reductions in test loss of 28.37% and 32.17%, respectively. Voxel‐wise correlation analysis also revealed that ΔB 0 and four other CEST parameters from the KAN and LKAN had higher average Pearson coefficients than MLP by 1.57% and 2.84%, indicating superior performance. LKAN exhibited a shorter average training time by 37.26% and a smaller average test loss by 5.29% compared to the KAN. Furthermore, our results demonstrated that even smaller KAN and LKAN could achieve better accuracy than MLPs, with both KAN and LKAN showing greater robustness to noisy data compared to MLP.

Conclusion

This study demonstrates the feasibility of KAN and LKAN for CEST MRI data analysis, highlighting their superiority over MLP. The findings suggest that CEST‐KAN and CEST‐LKAN have the potential to be robust and reliable post‐analysis tools for CEST MRI in clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedBrainHumansAdultMaleFemaleHealthy VolunteersAlgorithmsReproducibility of ResultsYoung Adult

Stichwörter der Autor:innen

Kolmogorov‐Arnold network (KAN)Lorentzian‐KAN (LKAN)chemical exchange saturation transfer (CEST)human brainmulti‐pool Lorentzian fitting (MPLF)

Autor:innen und Institutionen

  • Laboratory of Advanced Imaging in Medicine (AIM), Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China.

ORCID-Profile: Huabin Zhang, Jianpan Huang

Förderung

  • National Natural Science Foundation of China
  • University of Hong Kong

Zitieren

APA

Wang, J., Cai, P., Wang, Z., Zhang, H., & Huang, J. (2025). CEST MRI data analysis using Kolmogorov‐Arnold network ( KAN ) and Lorentzian ‐ KAN ( LKAN ) models. Magnetic Resonance in Medicine, 94(3), 1301-1317. https://doi.org/10.1002/mrm.30548

Vancouver

Wang J, Cai P, Wang Z, Zhang H, Huang J. CEST MRI data analysis using Kolmogorov‐Arnold network ( KAN ) and Lorentzian ‐ KAN ( LKAN ) models. Magnetic Resonance in Medicine. 2025;94(3):1301-1317. doi:10.1002/mrm.30548

BibTeX
@article{Wang2025,
  author = {Wang, Jiawen and Cai, Pei and Wang, Ziyan and Zhang, Huabin and Huang, Jianpan},
  title = {CEST MRI data analysis using Kolmogorov‐Arnold network ( KAN ) and Lorentzian ‐ KAN ( LKAN ) models},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  volume = {94},
  number = {3},
  pages = {1301--1317},
  doi = {10.1002/mrm.30548}
}
Kostenlos starten →