EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inline automatic quality control of 2D phase‐contrast flow MRI for subject‐specific scan time adaptation

Pierre Daudé iD, Rajiv Ramasawmy iD, Ahsan Javed iD, Robert J Lederman iD, Kelvin Chow iD, Adrienne E Campbell-Washburn iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Pierre Daudé und 5 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes …. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio, Image Processing, Computer-Assisted, Quality Control, Magnetic Resonance Imaging. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Intramural NIH HHS, NHLBI Division of Intramural Research, Division of Intramural Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop an inline automatic quality control to achieve consistent diagnostic image quality with subject‐specific scan time, and to demonstrate this method for 2D phase‐contrast flow MRI to reach a predetermined SNR.

Methods

We designed a closed‐loop feedback framework between image reconstruction and data acquisition to intermittently check SNR (every 20 s) and automatically stop the acquisition when a target SNR is achieved. A free‐breathing 2D pseudo‐golden‐angle spiral phase‐contrast sequence was modified to listen for image‐quality messages from the reconstructions. Ten healthy volunteers and 1 patient were imaged at 0.55 T. Target SNR was selected based on retrospective analysis of cardiac output error, and performance of the automatic SNR‐driven “stop” was assessed inline.

Results

SNR calculation and automated segmentation was feasible within 20 s with inline deployment. The SNR‐driven acquisition time was 2 min 39 s ± 67 s (aorta) and 3 min ± 80 s (main pulmonary artery) with a min/max acquisition time of 1 min 43 s/4 min 52 s (aorta) and 1 min 43 s/5 min 50 s (main pulmonary artery) across 6 healthy volunteers, while ensuring a diagnostic measurement with relative absolute error in quantitative flow measurement lower than 2.1% (aorta) and 6.3% (main pulmonary artery).

Conclusion

The inline quality control enables subject‐specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject‐specific scan time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal-To-Noise RatioImage Processing, Computer-AssistedQuality ControlMagnetic Resonance ImagingHumansAdultMaleHealthy VolunteersAlgorithmsFemalePulmonary ArteryAortaImage Interpretation, Computer-AssistedRetrospective StudiesRespirationReproducibility of Results

Stichwörter der Autor:innen

inline processingphase contrast flowquality assessmentscan time

Autor:innen und Institutionen

  • Laboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Laboratory of Cardiovascular Intervention, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Siemens Healthcare Ltd., Calgary, Alberta, Canada.

ORCID-Profile: Pierre Daudé, Rajiv Ramasawmy, Ahsan Javed, Robert J Lederman, Kelvin Chow, Adrienne E Campbell-Washburn

Förderung

  • Intramural NIH HHS
  • NHLBI Division of Intramural Research
  • Division of Intramural Research

Zitieren

APA

Daudé, P., Ramasawmy, R., Javed, A., Lederman, R. J., Chow, K., & Campbell-Washburn, A. E. (2024). Inline automatic quality control of 2D phase‐contrast flow MRI for subject‐specific scan time adaptation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30083

Vancouver

Daudé P, Ramasawmy R, Javed A, Lederman RJ, Chow K, Campbell-Washburn AE. Inline automatic quality control of 2D phase‐contrast flow MRI for subject‐specific scan time adaptation. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30083

BibTeX
@article{Daud2024,
  author = {Daudé, Pierre and Ramasawmy, Rajiv and Javed, Ahsan and Lederman, Robert J and Chow, Kelvin and Campbell-Washburn, Adrienne E},
  title = {Inline automatic quality control of 2D phase‐contrast flow MRI for subject‐specific scan time adaptation},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30083}
}
Kostenlos starten →