Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Xin Shen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Brain, Multiple Sclerosis. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: US Department of Defense, Multiple Sclerosis Research Program, U.S. Department of Defense.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to develop a new high‐resolution MRI sequence for the imaging of the ultra‐short transverse relaxation time (uT 2 ) components in the brain, while simultaneously providing proton density (PD) contrast for reference and quantification. Theory The sequence combines low flip angle balanced SSFP (bSSFP) and UTE techniques, together with a 3D dual‐echo rosette k‐space trajectory for readout.

Methods

The expected image contrast was evaluated by simulations. A study cohort of six healthy volunteers and eight multiple sclerosis (MS) patients was recruited to test the proposed sequence. Subtraction between two TEs was performed to extract uT 2 signals. In addition, conventional longitudinal relaxation time (T 1 ) weighted, T 2 ‐weighted, and PD‐weighted MRI sequences were also acquired for comparison.

Results

Typical PD‐contrast was found in the second TE images, while uT 2 signals were selectively captured in the first TE images. The subtraction images presented signals primarily originating from uT 2 components, but only if the first TE is short enough. Lesions in the MS subjects showed hyperintense signals in the second TE images but were hypointense signals in the subtraction images. The lesions had significantly lower signal intensity in subtraction images than normal white matter (WM), which indicated a reduction of uT 2 components likely associated with myelin.

Conclusion

3D isotropic sub‐millimeter (0.94 mm) spatial resolution images were acquired with the novel bSSFP UTE sequence within 3 min. It provided easy extraction of uT 2 signals and PD‐contrast for reference within a single acquisition.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMagnetic Resonance ImagingBrainMultiple SclerosisHumansAdultMaleFemaleAlgorithmsMiddle AgedImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedHealthy VolunteersComputer Simulation

Stichwörter der Autor:innen

3D rosette trajectorybalanced steady‐state free precessionmultiple sclerosisultra‐short echo time

Autor:innen und Institutionen

  • Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
  • Department of Brain and Behavioral Sciences, University of Pavia, Pavia, Italy.
  • Department of Neuroradiology, IRCCS Mondino Foundation, Pavia, Italy.
  • Neurology, University of California San Francisco, San Francisco, California, USA.
  • School of Health Science, Purdue University, West Lafayette, Indiana, USA.
  • Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.

ORCID-Profile: Xin Shen, Xiaoxi Liu, Uzay Emir, Peder E Z Larson

Förderung

  • US Department of Defense, Multiple Sclerosis Research Program
  • U.S. Department of Defense

Zitieren

APA

Shen, X., Caverzasi, E., Yang, Y., Liu, X., Green, A., Henry, R. G., Emir, U., & Larson, P. E. Z. (2024). 3D balanced SSFP UTE MRI for multiple contrasts whole brain imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30093

Vancouver

Shen X, Caverzasi E, Yang Y, Liu X, Green A, Henry RG, et al. 3D balanced SSFP UTE MRI for multiple contrasts whole brain imaging. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30093

BibTeX
@article{Shen2024,
  author = {Shen, Xin and Caverzasi, Eduardo and Yang, Yang and Liu, Xiaoxi and Green, Ari and Henry, Roland G and Emir, Uzay and Larson, Peder E Z},
  title = {3D balanced SSFP UTE MRI for multiple contrasts whole brain imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30093}
}
Kostenlos starten →