EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

3D virtual biopsy of in vivo pH and metabolism using PRESS and semi‐ LASER MRS of hyperpolarized 13 C nuclei

Wolfgang Gottwald iD, Luca Nagel iD, Martin Grashei iD, Sebastian Bauer, Nadine Setzer, Florian Gaksch, Sandra Sühnel, Jason G Skinner, Rickmer Braren, Irina Heid, Geoffrey J Topping, Franz Schilling iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30544 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Wolfgang Gottwald und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, TUM School of Medicine and Health, TUM University Hospital, Klinikum Rechts der Isar, Technical University of Munich,…. Hauptthemen laut MEDLINE: Pancreatic Neoplasms, Carcinoma, Pancreatic Ductal, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Bildung und Forschung, DFG (Deutsche Forschungsgemeinschaft), German Research Foundation, European Union.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop and evaluate sequences for multi‐voxel magnetic resonance spectroscopy using hyperpolarized molecules.

Methods

A standard single voxel PRESS sequence was extended to acquire multiple voxels consecutively. Its SNR was compared against a 2D FID‐CSI with both 1 H and hyperpolarized 13 C nuclei in phantoms and in a healthy mouse at 7T. This sequence was also used to determine tumor pH and metabolic activity in an endogenous murine pancreatic ductal adenocarcinoma model. Furthermore, a semi‐LASER sequence, using adiabatic full passage RF pulses for refocusing, was implemented. Multi‐voxel PRESS and semi‐LASER were then compared in healthy mice for measuring metabolic activity and pH using hyperpolarized [1‐ 13 C]pyruvate and [1,5‐ 13 C 2 ]Z‐OMPD, respectively.

Results

Multi‐voxel PRESS and semi‐LASER detected 13 C metabolites in mouse kidneys and endogenous pancreatic ductal adenocarcinoma (PDAC) tumors with SNR comparable to that of standard 2D FID‐CSI. They enable fast MRS with a high spectral resolution that is highly customizable to recover spectra from regions not coverable by a single CSI slice.

Conclusion

For the first time, we show hyperpolarized MRS using multi‐voxel PRESS and semi‐LASER sequences for hyperpolarized 13 C‐labeled molecules. By implementing a semi‐LASER sequence using adiabatic full passage refocusing pulses, RF saturation was reduced. Semi‐LASER allows flexible overlapping of voxel refocusing planes, while for PRESS, signal from these regions is attenuated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pancreatic NeoplasmsCarcinoma, Pancreatic DuctalImaging, Three-DimensionalAnimalsMiceCarbon IsotopesPhantoms, ImagingHydrogen-Ion ConcentrationMagnetic Resonance SpectroscopyBiopsyPyruvic AcidKidneyLasersSignal-To-Noise RatioMagnetic Resonance Imaging

Stichwörter der Autor:innen

13C hyperpolarizationMR‐spectroscopypHpyruvatesemi‐LASER

Substanzen

Carbon IsotopesPyruvic AcidCarbon-13

Autor:innen und Institutionen

  • Department of Nuclear Medicine, TUM School of Medicine and Health, TUM University Hospital, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
  • Department of Physics, TUM School of Natural Sciences, Technical University of Munich, Garching, Germany.
  • Institute of Diagnostic and Interventional Radiology, TUM School of Medicine and Health, TUM University Hospital, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
  • German Cancer Consortium (DKTK), Partner Site Munich and German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany.

ORCID-Profile: Wolfgang Gottwald, Luca Nagel, Martin Grashei, Franz Schilling

Förderung

  • Bundesministerium für Bildung und Forschung
  • DFG (Deutsche Forschungsgemeinschaft), German Research Foundation
  • European Union
  • Deutsche Forschungsgemeinschaft
  • European Commission

Zitieren

APA

Gottwald, W., Nagel, L., Grashei, M., Bauer, S., Setzer, N., Gaksch, F., Sühnel, S., Skinner, J. G., Braren, R., Heid, I., Topping, G. J., & Schilling, F. (2025). 3D virtual biopsy of in vivo pH and metabolism using PRESS and semi‐ LASER MRS of hyperpolarized 13 C nuclei. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30544

Vancouver

Gottwald W, Nagel L, Grashei M, Bauer S, Setzer N, Gaksch F, et al. 3D virtual biopsy of in vivo pH and metabolism using PRESS and semi‐ LASER MRS of hyperpolarized 13 C nuclei. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30544

BibTeX
@article{Gottwald2025,
  author = {Gottwald, Wolfgang and Nagel, Luca and Grashei, Martin and Bauer, Sebastian and Setzer, Nadine and Gaksch, Florian and Sühnel, Sandra and Skinner, Jason G and Braren, Rickmer and Heid, Irina and Topping, Geoffrey J and Schilling, Franz},
  title = {3D virtual biopsy of in vivo pH and metabolism using PRESS and semi‐ LASER MRS of hyperpolarized 13 C nuclei},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30544}
}
Kostenlos starten →