Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Daiki Tamada und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Iron Overload, Liver, Breath Holding, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIDDK NIH HHS, NCATS NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Purpose
Diagnosis and treatment monitoring of iron overload increasingly relies on non‐invasive MRI‐based measurement of liver iron concentration (LIC). Liver R 2 mapping is known to correlate well with LIC. However, traditional spin‐echo based R 2 mapping methods have drawbacks such as long acquisition times and limited volumetric coverage. In this work, we present an optimized phase‐based R 2 mapping method to quantify whole‐liver R 2 in iron overload patients within a single breathhold. Theory and Methods A recently developed phase‐based R 2 mapping method is optimized in this study to improve estimation of high R 2 values using reduced TR, spatial averaging, and R 1 correction. Using Bloch equation simulations, the proposed optimization method was evaluated. Furthermore, the impact of fat on R 2 bias was investigated through simulations. The feasibility of the optimized phase‐based R 2 method was assessed in healthy volunteers and patients with iron overload and compared to reference STEAM‐MRS R 2 measurements.
Results
Simulations demonstrate that a shorter TR extends the dynamic range of R 2 estimation to higher values and that averaging of signal phase before R 2 estimation is necessary when R 2 is high. Phantom experiments also demonstrate reduced phase‐based R 2 bias using R 1 correction. Good agreement (1.5 T: r 2 = 0.76, 3.0 T: r 2 = 0.70) between the modified phase‐based R 2 method and reference STEAM R 2 was found in healthy volunteers and iron overload patients over a wide range of LIC values.
Conclusion
This study demonstrates the feasibility of the proposed phase‐based R 2 method to accurately measure whole‐liver R 2 mapping in severe iron overloaded patients during a single breathhold.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Emergency Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: Daiki Tamada, Diego Hernando, Scott B Reeder
Förderung
- NIDDK NIH HHS
- NCATS NIH HHS
- NIBIB NIH HHS
- GE Healthcare
- National Institute of Diabetes and Digestive and Kidney Diseases
- National Center for Advancing Translational Sciences
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Tamada, D., Navaratna, R., Weaver, J. M., Hernando, D., & Reeder, S. B. (2025). Whole liver phase‐based R2 mapping in liver iron overload within a breath‐hold. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30461
Vancouver
Tamada D, Navaratna R, Weaver JM, Hernando D, Reeder SB. Whole liver phase‐based R2 mapping in liver iron overload within a breath‐hold. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30461
BibTeX
@article{Tamada2025,
author = {Tamada, Daiki and Navaratna, Ruvini and Weaver, Jayse Merle and Hernando, Diego and Reeder, Scott B},
title = {Whole liver phase‐based R2 mapping in liver iron overload within a breath‐hold},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30461}
}
EUVIMED