EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Confounder‐corrected T 1 mapping in the liver through simultaneous estimation of T 1 , PDFF , R2*, and B1+ in a single breath‐hold acquisition

Nathan T Roberts iD, Daiki Tamada iD, Yavuz Muslu iD, Diego Hernando iD, Scott B Reeder iD

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29590 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Nathan T Roberts und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Wisconsin - Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Liver, Non-alcoholic Fatty Liver Disease. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIDDK NIH HHS, NCATS NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Quantitative volumetric T 1 mapping in the liver has the potential to aid in the detection, diagnosis, and quantification of liver fibrosis, inflammation, and spatially resolved liver function. However, accurate measurement of hepatic T 1 is confounded by the presence of fat and inhomogeneous excitation. Furthermore, scan time constraints related to respiratory motion require tradeoffs of reduced volumetric coverage and/or increased acquisition time. This work presents a novel 3D acquisition and estimation method for confounder‐corrected T 1 measurement over the entire liver within a single breath‐hold through simultaneous estimation of T 1 , fat and . Theory and Methods The proposed method combines chemical shift encoded MRI and variable flip angle MRI with a mapping technique to enable confounder‐corrected T 1 mapping. The method was evaluated theoretically and demonstrated in both phantom and in vivo acquisitions at 1.5 and 3.0T. At 1.5T, the method was evaluated both pre‐ and post‐ contrast enhancement in healthy volunteers.

Results

The proposed method demonstrated excellent linear agreement with reference inversion‐recovery spin‐echo based T 1 in phantom acquisitions at both 1.5 and 3.0T, with minimal bias (5.2 and 45 ms, respectively) over T 1 ranging from 200–1200 ms. In vivo results were in general agreement with reference saturation‐recovery based 2D T 1 maps (SMART 1 Map, GE Healthcare).

Conclusion

The proposed 3D T 1 mapping method accounts for fat and confounders through simultaneous estimation of T 1 , , PDFF and . It demonstrates strong linear agreement with reference T 1 measurements, with low bias and high precision, and can achieve full liver coverage in a single breath‐hold.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverNon-alcoholic Fatty Liver DiseaseHumansBreath HoldingMagnetic Resonance ImagingLiver CirrhosisReproducibility of ResultsPhantoms, Imaging

Stichwörter der Autor:innen

B 1 + $$ {B}_1^{+} $$ mappingR 2 * $$ {R}_2^{\ast } $$ estimationPDFF estimationT1 mappingchemical shift encoded MRIquantitative MRIvariable flip angle MRI

Autor:innen und Institutionen

  • Department of Radiology, University of Wisconsin - Madison, Madison, Wisconsin, USA.
  • Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA.
  • Department of Biomedical Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA.
  • Department of Medical Physics, University of Wisconsin - Madison, Madison, Wisconsin, USA.
  • Department of Medicine, University of Wisconsin - Madison, Madison, Wisconsin, USA.
  • Department of Emergency Medicine, University of Wisconsin - Madison, Madison, Wisconsin, USA.

ORCID-Profile: Nathan T Roberts, Daiki Tamada, Yavuz Muslu, Diego Hernando, Scott B Reeder

Förderung

  • NIDDK NIH HHS
  • NCATS NIH HHS
  • National Institutes of Health
  • Institute for Clinical and Translational Research, University of Wisconsin, Madison
  • GE Healthcare
  • University of Wisconsin-Madison
  • Office of the Vice Chancellor for Research and Innovation
  • Wisconsin Alumni Research Foundation

Zitieren

APA

Roberts, N. T., Tamada, D., Muslu, Y., Hernando, D., & Reeder, S. B. (2023). Confounder‐corrected T 1 mapping in the liver through simultaneous estimation of T 1 , PDFF , R2*, and B1+ in a single breath‐hold acquisition. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29590

Vancouver

Roberts NT, Tamada D, Muslu Y, Hernando D, Reeder SB. Confounder‐corrected T 1 mapping in the liver through simultaneous estimation of T 1 , PDFF , R2*, and B1+ in a single breath‐hold acquisition. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29590

BibTeX
@article{Roberts2023,
  author = {Roberts, Nathan T and Tamada, Daiki and Muslu, Yavuz and Hernando, Diego and Reeder, Scott B},
  title = {Confounder‐corrected T 1 mapping in the liver through simultaneous estimation of T 1 , PDFF , R2*, and B1+ in a single breath‐hold acquisition},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29590}
}
Kostenlos starten →