Prospective motion correction for R2* and susceptibility mapping using spherical navigators
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30385 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Miriam Hewlett und 3 weiteren Autor:innen. Beteiligte Einrichtung: Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CIHR, Natural Sciences and Engineering Research Council of Canada, Canadian Institutes of Health Research.
Abstract (Originalsprache)
Purpose
To perform prospective motion correction (PMC) for improved and susceptibility mapping using a purely navigator‐based approach.
Methods
Spherical navigators (SNAVs) were combined with an additional FID readout for simultaneous measurement of motion and zeroth‐order field shifts. The resulting FIDSNAVs were interleaved for PMC of a multi‐echo gradient echo sequence with retrospective correction. Experiments were performed on a 3T scanner with a 32‐channel head coil. Performance was assessed in five volunteers with motion prompts derived from real unintentional motion trajectories.
Results
At short TEs, PMC alone was sufficient to achieve good image quality; at longer TEs, retrospective correction was often just as important for artifact reduction as motion correction. Both PMC and retrospective correction reduced error in and susceptibility maps for all participants. Residual artifacts were observed in the most severe motion case.
Conclusion
Combining SNAVs with an additional FID readout enables simultaneous motion and field correction with no additional hardware requirements, improving the fidelity of quantitative mapping in the presence of motion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada.
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada.
- Siemens Healthcare Limited, Oakville, Ontario, Canada.
ORCID-Profile: Miriam Hewlett, Omer Oran, Junmin Liu, Maria Drangova
Förderung
- CIHR
- Natural Sciences and Engineering Research Council of Canada
- Canadian Institutes of Health Research
Zitieren
APA
Hewlett, M., Oran, O., Liu, J., & Drangova, M. (2025). Prospective motion correction for R2* and susceptibility mapping using spherical navigators. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30385
Vancouver
Hewlett M, Oran O, Liu J, Drangova M. Prospective motion correction for R2* and susceptibility mapping using spherical navigators. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30385
BibTeX
@article{Hewlett2025,
author = {Hewlett, Miriam and Oran, Omer and Liu, Junmin and Drangova, Maria},
title = {Prospective motion correction for R2* and susceptibility mapping using spherical navigators},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30385}
}