Parallel‐transmission spatial spectral pulse design with local specific absorption rate control: Demonstration for robust uniform water‐selective excitation in the human brain at 7 T
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30346 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Xin Shao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Algorithms, Brain, Phantoms, Imaging, Water. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 86 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NINDS NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Purpose
To propose a novel method for parallel‐transmission (pTx) spatial‐spectral pulse design and demonstrate its utility for robust uniform water‐selective excitation (water excitation) across the entire brain. Theory and Methods Our design problem is formulated as a magnitude‐least‐squares minimization with joint RF and k‐space optimization under explicit specific‐absorption‐rate constraints. For improved robustness against off‐resonance effects, the spectral component of the excitation target is prescribed to have a water passband and a fat stopband. A two‐step algorithm was devised to solve our design problem, with Step 1 aiming to solve a reduced problem to find a sensible start point for Step 2 to solve the original problem. The efficacy of our pulse design was evaluated in simulation, phantom, and human experiments using the commercial Nova head coil. Universal pulses were also designed based on a 10‐subject training data set to demonstrate the utility of our method for plug‐and‐play pTx.
Results
For k T ‐points and spiral nonselective parameterizations, our design method outperformed the pTx interleaved binomial approach, reducing RMS error by up to about 35% for water excitation and about 97% for fat suppression (over a 200‐Hz bandwidth) while decreasing local specific absorption rate by about 30%. Both our subject‐specific and universal pulses improved water excitation, restoring signal loss in the cerebellum while suppressing fat signal even in regions of large susceptibility‐induced off‐resonances.
Conclusion
Demonstrated useful for 4D (3D spatial, one‐dimensional spectral) pTx spatial‐spectral pulse design, our proposed method provides an effective solution for robust volumetric uniform water excitation, holding a promise to many ultrahigh‐field applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
- Tiantan Neuroimaging Center of Excellence, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.
- Center for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota, Minneapolis, Minnesota, USA.
ORCID-Profile: Xin Shao, Hua Guo, Xiaoping Wu
Förderung
- NIBIB NIH HHS
- NINDS NIH HHS
- National Institutes of Health
Zitieren
APA
Shao, X., Zhang, Z., Ma, X., Liu, F., Guo, H., Ugurbil, K., & Wu, X. (2025). Parallel‐transmission spatial spectral pulse design with local specific absorption rate control: Demonstration for robust uniform water‐selective excitation in the human brain at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30346
Vancouver
Shao X, Zhang Z, Ma X, Liu F, Guo H, Ugurbil K, et al. Parallel‐transmission spatial spectral pulse design with local specific absorption rate control: Demonstration for robust uniform water‐selective excitation in the human brain at 7 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30346
BibTeX
@article{Shao2025,
author = {Shao, Xin and Zhang, Zhe and Ma, Xiaodong and Liu, Fan and Guo, Hua and Ugurbil, Kamil and Wu, Xiaoping},
title = {Parallel‐transmission spatial spectral pulse design with local specific absorption rate control: Demonstration for robust uniform water‐selective excitation in the human brain at 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30346}
}
EUVIMED