High‐quality FLORET UTE imaging for clinical translation
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30277 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Matthew M Willmering und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children's Hospital, Cincinnati, Ohio, USA. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Imaging, Three-Dimensional. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Cincinnati Children's Research Foundation, Cystic Fibrosis Foundation Research Development Program, Cystic Fibrosis Foundation.
Abstract (Originalsprache)
Purpose
To develop a robust 3D ultrashort‐TE (UTE) protocol that can reproducibly provide high‐quality images, assessed by the ability to yield clinically diagnostic images, and is suitable for clinical translation. Theory and Methods Building on previous work, a UTE sampled with Fermat looped orthogonally encoded trajectories (FLORET) was chosen as a starting point due to its shorter, clinically reasonable scan times. Modifications to previous FLORET implementations included gradient waveform frequency limitations, a new trajectory ordering scheme, a balanced SSFP implementation, fast gradient spoiling, and full inline reconstruction. FLORET images were collected in phantoms and humans on multiple scanners and sites to demonstrate these improvements.
Results
The updates to FLORET provided high‐quality images in phantom, musculoskeletal, and pulmonary applications. The gradient waveform modifications and new trajectory ordering scheme significantly reduced visible artifacts. Fast spoiling reduced acquisition time by 20%–28%. Across the various scanners and sites, the inline image quality was consistent and of diagnostic quality. Total image acquisition plus reconstruction time was less than 4 min for musculoskeletal and pulmonary applications with reconstructions taking less than 1 min.
Conclusion
Recently developed improvements for the FLORET sequence have enabled robust, high‐quality UTE acquisitions with short acquisition and reconstruction times. This enables clinical UTE imaging as demonstrated by the implementation of the sequence and acquisition on five MRI scanners, at three different sites, without the need for any additional system characterization or measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children's Hospital, Cincinnati, Ohio, USA.
- Department of Pediatrics, University of Cincinnati School of Medicine, Cincinnati, Ohio, USA.
- Philips Healthcare, Rochester, Minnesota, USA.
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Philips Healthcare, Nashville, Tennessee, USA.
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
ORCID-Profile: Matthew M Willmering, Guruprasad Krishnamoorthy
Förderung
- Cincinnati Children's Research Foundation
- Cystic Fibrosis Foundation Research Development Program
- Cystic Fibrosis Foundation
Zitieren
APA
Willmering, M. M., Krishnamoorthy, G., Robison, R. K., Rosenberg, J. T., Woods, J. C., & Pipe, J. G. (2025). High‐quality FLORET UTE imaging for clinical translation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30277
Vancouver
Willmering MM, Krishnamoorthy G, Robison RK, Rosenberg JT, Woods JC, Pipe JG. High‐quality FLORET UTE imaging for clinical translation. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30277
BibTeX
@article{Willmering2025,
author = {Willmering, Matthew M and Krishnamoorthy, Guruprasad and Robison, Ryan K and Rosenberg, Jens T and Woods, Jason C and Pipe, James G},
title = {High‐quality FLORET UTE imaging for clinical translation},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30277}
}
EUVIMED