Feasibility of interleaved multislice averaged magnetization inversion‐recovery acquisitions of the spinal cord
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30223 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2024. Written by Matthias Weigel and 3 co-authors. Institution: Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, Switzerland. Major MEDLINE topics: Spinal Cord, Feasibility Studies, Algorithms. 37 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Purpose
To establish an interleaved multislice variant of the averaged magnetization inversion‐recovery acquisitions (AMIRA) approach for 2D spinal cord imaging with increased acquisition efficiency compared with the conventional 2D single‐slice approach(es), and to determine essential prerequisites for a working interleaved multislice AMIRA approach in practice.
Methods
The general AMIRA concept is based on an inversion recovery–prepared, segmented, and time‐limited cine balanced SSFP sequence, generating images of different contrast. For AMIRA imaging of multiple, independent slices in a 2D interleaved fashion, a slice loop within the acquisition loops was programmed. The former non‐selective inversions were replaced with slice‐selective inversions with user‐definable slice thickness.
Results
The thickness of the slice‐selective inversion in 2D interleaved multislice AMIRA should be doubled compared with the manufacturer's standard setting to avoid an increased sensitivity to flow and pulsation effects particularly in the CSF. However, this solution also limits its practical applicability, as slices located at directly adjacent vertebrae cannot be imaged together. Successful interleaved two‐slice AMIRA imaging for a “reference” in vivo protocol with 0.50 × 0.50 mm 2 in‐plane resolution and 8‐mm slice thickness is demonstrated, therefore halving its acquisition time per slice from 3 min down to 1.5 min.
Conclusion
The investigated 2D interleaved two‐slice AMIRA variant facilitates spinal cord imaging that maintains similar contrast and the same resolution as the conventional 2D single‐slice AMIRA approach, but does so with a halved acquisition time.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, Switzerland.
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
- Translational Imaging in Neurology (ThINk) Basel, Department of Biomedical Engineering, Faculty of Medicine, University Hospital Basel and University of Basel, Basel, Switzerland.
- Department of Neurology, University Hospital Basel, Basel, Switzerland.
- Research Center for Clinical Neuroimmunology and Neuroscience Basel (RC2NB), University Hospital Basel and University of Basel, Basel, Switzerland.
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Switzerland.
ORCID profiles: Matthias Weigel, Oliver Bieri
Cite
APA
Weigel, M., Celicanin, Z., Haas, T., & Bieri, O. (2024). Feasibility of interleaved multislice averaged magnetization inversion‐recovery acquisitions of the spinal cord. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30223
Vancouver
Weigel M, Celicanin Z, Haas T, Bieri O. Feasibility of interleaved multislice averaged magnetization inversion‐recovery acquisitions of the spinal cord. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30223
BibTeX
@article{Weigel2024,
author = {Weigel, Matthias and Celicanin, Zarko and Haas, Tanja and Bieri, Oliver},
title = {Feasibility of interleaved multislice averaged magnetization inversion‐recovery acquisitions of the spinal cord},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30223}
}
EUVIMED