EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Feasibility of interleaved multislice averaged magnetization inversion‐recovery acquisitions of the spinal cord

Matthias Weigel iD, Zarko Celicanin, Tanja Haas, Oliver Bieri iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30223 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Matthias Weigel and 3 co-authors. Institution: Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, Switzerland. Major MEDLINE topics: Spinal Cord, Feasibility Studies, Algorithms. 37 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To establish an interleaved multislice variant of the averaged magnetization inversion‐recovery acquisitions (AMIRA) approach for 2D spinal cord imaging with increased acquisition efficiency compared with the conventional 2D single‐slice approach(es), and to determine essential prerequisites for a working interleaved multislice AMIRA approach in practice.

Methods

The general AMIRA concept is based on an inversion recovery–prepared, segmented, and time‐limited cine balanced SSFP sequence, generating images of different contrast. For AMIRA imaging of multiple, independent slices in a 2D interleaved fashion, a slice loop within the acquisition loops was programmed. The former non‐selective inversions were replaced with slice‐selective inversions with user‐definable slice thickness.

Results

The thickness of the slice‐selective inversion in 2D interleaved multislice AMIRA should be doubled compared with the manufacturer's standard setting to avoid an increased sensitivity to flow and pulsation effects particularly in the CSF. However, this solution also limits its practical applicability, as slices located at directly adjacent vertebrae cannot be imaged together. Successful interleaved two‐slice AMIRA imaging for a “reference” in vivo protocol with 0.50 × 0.50 mm 2 in‐plane resolution and 8‐mm slice thickness is demonstrated, therefore halving its acquisition time per slice from 3 min down to 1.5 min.

Conclusion

The investigated 2D interleaved two‐slice AMIRA variant facilitates spinal cord imaging that maintains similar contrast and the same resolution as the conventional 2D single‐slice AMIRA approach, but does so with a halved acquisition time.

Subjects

MeSH terms (MEDLINE)

Spinal CordFeasibility StudiesAlgorithmsHumansMagnetic Resonance ImagingReproducibility of ResultsImage EnhancementSensitivity and SpecificityImage Interpretation, Computer-AssistedMaleAdultImage Processing, Computer-AssistedFemale

Author keywords

AMIRAaveraged magnetization inversion recovery acquisitionsbalanced SSFPinterleaved multisliceinversion recoveryspinal cord

Authors and institutions

  • Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, Switzerland.
  • Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
  • Translational Imaging in Neurology (ThINk) Basel, Department of Biomedical Engineering, Faculty of Medicine, University Hospital Basel and University of Basel, Basel, Switzerland.
  • Department of Neurology, University Hospital Basel, Basel, Switzerland.
  • Research Center for Clinical Neuroimmunology and Neuroscience Basel (RC2NB), University Hospital Basel and University of Basel, Basel, Switzerland.
  • Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Switzerland.

ORCID profiles: Matthias Weigel, Oliver Bieri

Cite

APA

Weigel, M., Celicanin, Z., Haas, T., & Bieri, O. (2024). Feasibility of interleaved multislice averaged magnetization inversion‐recovery acquisitions of the spinal cord. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30223

Vancouver

Weigel M, Celicanin Z, Haas T, Bieri O. Feasibility of interleaved multislice averaged magnetization inversion‐recovery acquisitions of the spinal cord. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30223

BibTeX
@article{Weigel2024,
  author = {Weigel, Matthias and Celicanin, Zarko and Haas, Tanja and Bieri, Oliver},
  title = {Feasibility of interleaved multislice averaged magnetization inversion‐recovery acquisitions of the spinal cord},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30223}
}
Start for free →