Feasibility of Half-Dose Gadoxetic Acid-Enhanced Liver MRI at 5.0 T: A Prospective Intrapatient Comparison with Full-Dose 3.0 T
Academic Radiology · 2026-05 · 33 (5) · 1924-1934
DOI: 10.1016/j.acra.2026.02.012 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Academic Radiology, 2026-05. Verfasst von Yuannan Hu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Hubei Provincial Engineering Research Center of Multimodal Medical Imaging Technology and Clinical Application, Wuhan Clinical Research and Developme…. Hauptthemen laut MEDLINE: Gadolinium DTPA, Magnetic Resonance Imaging, Liver Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wuhan University, National Natural Science Foundation of China, Health Commission of Hubei Province.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: This study aims to determine if half-dose gadoxetic acid-enhanced liver magnetic resonance imaging (MRI) at 5.0 T is feasible by comparing with full-dose MRI at 3.0 T. MATERIALS AND METHODS: 19 patients with liver disease underwent both full-dose (0.025 mmol/kg) gadoxetic acid-enhanced 3.0-T MRI and half-dose (0.0125 mmol/kg) 5.0-T MRI. Quantitative image quality was assessed by measuring the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast enhancement index (CEI) in liver and hepatic lesions. Qualitative image quality and respiratory motion artifacts were evaluated. Statistical comparisons were performed using paired t-tests or the Wilcoxon signed-rank test. RESULTS: Half dose 5.0-T MRI yielded significantly higher SNRs in liver and hepatic lesions compared to full-dose 3.0-T MRI (all P < 0.001). The 15-minute hepatobiliary phase (HBP) at 5.0 T achieved image quality comparable to 20-minute HBP at 3.0 T. Specifically, at the 15-minute HBP, the 5.0-T protocol demonstrated significantly higher liver SNR (77.24 ± 12.08 vs. 51.84 ± 8.18 at 20 min for 3.0 T; P < 0.001) and liver-to-lesion CNR (38.93 ± 15.56 vs. 25.37 ± 9.43; P < 0.01). Additionally, respiratory motion artifacts in the early arterial phase were significantly reduced at 5.0 T (1.12 ± 0.33 vs. 1.62 ± 0.86; P < 0.05). CONCLUSION: Liver 5.0-T MRI with a half-dose of gadoxetic acid maintains diagnostic image quality while enabling a 25% reduction in HBP acquisition time and mitigating motion artifacts. This technique represents a viable strategy to improve scanning efficiency and patient safety in gadoxetic acid-enhanced liver imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hubei Provincial Engineering Research Center of Multimodal Medical Imaging Technology and Clinical Application, Wuhan Clinical Research and Development Center of Brain Resuscitation and Functional Imaging, and Departmen…
Förderung
- Wuhan University
- National Natural Science Foundation of China
- Health Commission of Hubei Province
Zitieren
APA
Hu, Y., Liao, R., Mei, L., Hu, J., Zhou, F., Deng, M., & Xu, H. (2026). Feasibility of Half-Dose Gadoxetic Acid-Enhanced Liver MRI at 5.0 T: A Prospective Intrapatient Comparison with Full-Dose 3.0 T. Academic Radiology, 33(5), 1924-1934. https://doi.org/10.1016/j.acra.2026.02.012
Vancouver
Hu Y, Liao R, Mei L, Hu J, Zhou F, Deng M, et al. Feasibility of Half-Dose Gadoxetic Acid-Enhanced Liver MRI at 5.0 T: A Prospective Intrapatient Comparison with Full-Dose 3.0 T. Academic Radiology. 2026;33(5):1924-1934. doi:10.1016/j.acra.2026.02.012
BibTeX
@article{Hu2026,
author = {Hu, Yuannan and Liao, Rufang and Mei, Liejun and Hu, Jinxiang and Zhou, Fenfang and Deng, Ming and Xu, Haibo},
title = {Feasibility of Half-Dose Gadoxetic Acid-Enhanced Liver MRI at 5.0 T: A Prospective Intrapatient Comparison with Full-Dose 3.0 T},
journal = {Academic Radiology},
year = {2026},
volume = {33},
number = {5},
pages = {1924--1934},
doi = {10.1016/j.acra.2026.02.012}
}
EUVIMED