Differential diagnosis of thyroid nodules by DCE-MRI based on compressed sensing volumetric interpolated breath-hold examination: A feasibility study
Magnetic Resonance Imaging · 2024
DOI: 10.1016/j.mri.2024.05.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Junhao Huang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Chongqing University Cancer Hospital, School of Medicine, Chongqing University, Chongqing, China. Hauptthemen laut MEDLINE: Thyroid Nodule, Feasibility Studies, Magnetic Resonance Imaging, Breath Holding. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Chongqing Municipality.
Abstract (Originalsprache)
OBJECTIVES: To explore the potential and performance of quantitative and semi-quantitative parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on compressed sensing volumetric interpolated breath-hold (CS-VIBE) examination in the differential diagnosis of thyroid nodules. MATERIALS AND METHODS: A total of 208 patients with 259 thyroid nodules scheduled for surgery operation were prospectively recruited. All participants underwent routine and DCE-MRI. DCE-MRI quantitative parameters [Ktrans, Kep, Ve], semi-quantitative parameters [wash-in, wash-out, time to peak (TTP), arrival time (AT), peak enhancement intensity (PEI), and initial area under curve in 60 s (iAUC)] and time-intensity curve (TIC) types were analyzed. Differential diagnostic performances were assessed using area under the receiver operating characteristic curve (AUC) and compared with the Delong test. RESULTS: Ktrans, Kep, Ve, wash-in, wash-out, PEI and iAUC were statistically significantly different between malignant and benign nodules (P < 0.001). Among these parameters, ROC analysis revealed that Ktrans showed the highest diagnostic performance in the differentiation of benign and malignant nodules, followed by wash-in. ROC analysis also revealed that Ktrans achieved the best diagnostic performance for distinguishing papillary thyroid carcinoma (PTC) from non-PTC, follicular adenoma (FA) from non-FA, nodular goiter (NG) from non-NG, with AUC values of 0.854, 0.895 and 0.609, respectively. Type III curve is frequently observed in benign thyroid nodules, accounting for 77.4% (82/106). While malignant nodules are more common in type II, accounting for 57.5% (88/153). CONCLUSION: Thyroid examination using CS-VIBE based DCE-MRI is a feasible, non-invasive method to identify benign and malignant thyroid nodules and pathological types.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Chongqing University Cancer Hospital, School of Medicine, Chongqing University, Chongqing, China.
- MR Collaborations, Siemens Healthineers Ltd., Chengdu, China.
- MR Applications Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany.
- Head and Neck Cancer Center, Chongqing University Cancer Hospital, School of Medicine, Chongqing University, Chongqing, China.
- Department of Radiology, Chongqing University Cancer Hospital, School of Medicine, Chongqing University, Chongqing, China. Electronic address: zhangjq_radiol@foxmail.com.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Chongqing Municipality
Zitieren
APA
Huang, J., Liu, D., Chen, J., Wang, X., Tang, L., Zhang, J., Tan, Y., Lan, X., Yin, T., Nickel, D., Wu, J., & Zhang, J. (2024). Differential diagnosis of thyroid nodules by DCE-MRI based on compressed sensing volumetric interpolated breath-hold examination: A feasibility study. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.05.006
Vancouver
Huang J, Liu D, Chen J, Wang X, Tang L, Zhang J, et al. Differential diagnosis of thyroid nodules by DCE-MRI based on compressed sensing volumetric interpolated breath-hold examination: A feasibility study. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.05.006
BibTeX
@article{Huang2024,
author = {Huang, Junhao and Liu, Daihong and Chen, Jiao and Wang, Xiaoxia and Tang, Lin and Zhang, Jing and Tan, Yong and Lan, Xiaosong and Yin, Ting and Nickel, Dominik and Wu, Jian and Zhang, Jiuquan},
title = {Differential diagnosis of thyroid nodules by DCE-MRI based on compressed sensing volumetric interpolated breath-hold examination: A feasibility study},
journal = {Magnetic Resonance Imaging},
year = {2024},
doi = {10.1016/j.mri.2024.05.006}
}