Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Zekang Ding und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shangha…. Hauptthemen laut MEDLINE: Artifacts, Diaphragm, Magnetic Resonance Imaging, Algorithms. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanghai Science and Technology Commission Explorer Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To reduce the ringing artifacts of the motion‐resolved images in free‐breathing dynamic pulmonary MRI.

Methods

A golden‐step based interleaving (GSI) technique was proposed to reduce ringing artifacts induced by diaphragm drifting. The pulmonary MRI data were acquired using a superior–inferior navigated 3D radial UTE sequence in an interleaved manner during free breathing. Successive interleaves were acquired in an incoherent fashion along the polar direction. Four‐dimensional images were reconstructed from the motion‐resolved k‐space data obtained by retrospectively binning. The reconstruction algorithms included standard nonuniform fast Fourier transform (NUFFT), Voronoi‐density‐compensated NUFFT, extra‐dimensional UTE, and motion‐state weighted motion‐compensation reconstruction. The proposed interleaving technique was compared with a conventional sequential interleaving (SeqI) technique on a phantom and eight subjects.

Results

The quantified ringing artifacts level in the motion‐resolved image is positively correlated with the quantified nonuniformity level of the corresponding k‐space. The nonuniformity levels of the end‐expiratory and end‐inspiratory k‐space binned from GSI data (0.34 ± 0.07, 0.33 ± 0.05) are significantly lower with statistical significance ( p < 0.05) than that binned from SeqI data (0.44 ± 0.11, 0.42 ± 0.12). Ringing artifacts are substantially reduced in the dynamic images of eight subjects acquired using the proposed technique in comparison with that acquired using the conventional SeqI technique.

Conclusion

Ringing artifacts in the motion‐resolved images induced by diaphragm drifting can be reduced using the proposed GSI technique for free‐breathing dynamic pulmonary MRI. This technique has the potential to reduce ringing artifacts in free‐breathing liver and kidney MRI based on full‐echo interleaved 3D radial acquisition.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsDiaphragmMagnetic Resonance ImagingAlgorithmsPhantoms, ImagingLungImaging, Three-DimensionalRespirationHumansAdultMaleFemaleMotionImage Processing, Computer-AssistedImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

diaphragm driftingdynamic pulmonary MRIfree‐breathinginterleaved acquisitionk‐space uniformityringing artifacts

Autor:innen und Institutionen

  • National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Central Research Institute, United Imaging Group, Shanghai, China.

ORCID-Profile: Zekang Ding

Förderung

  • National Natural Science Foundation of China
  • Shanghai Science and Technology Commission Explorer Program

Zitieren

APA

Ding, Z., She, H., Chen, Q., & Du, Y. P. (2024). Reduction of ringing artifacts induced by diaphragm drifting in free‐breathing dynamic pulmonary MRI using 3D koosh‐ball acquisition. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30207

Vancouver

Ding Z, She H, Chen Q, Du YP. Reduction of ringing artifacts induced by diaphragm drifting in free‐breathing dynamic pulmonary MRI using 3D koosh‐ball acquisition. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30207

BibTeX
@article{Ding2024,
  author = {Ding, Zekang and She, Huajun and Chen, Qun and Du, Yiping P},
  title = {Reduction of ringing artifacts induced by diaphragm drifting in free‐breathing dynamic pulmonary MRI using 3D koosh‐ball acquisition},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30207}
}
Kostenlos starten →