EUVIMEDOpdag EUVIMED
Open access · CC BY-NC 4.0

Improving MR axon radius estimation in human white matter using spiral acquisition and field monitoring

Marten Veldmann iD, Luke J Edwards iD, Kerrin J Pine iD, Philipp Ehses iD, Mónica Ferreira iD, Nikolaus Weiskopf iD, Tony Stoecker iD

Magnetic Resonance in Medicine · 2024-11 · 92 (5) · 1898-1912

DOI: 10.1002/mrm.30180 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2024-05-31. Written by Marten Veldmann and 6 co-authors. Institution: MR Physics, German Center for Neurodegenerative Diseases (DZNE) e.V, Bonn, Germany. Major MEDLINE topics: White Matter, Axons, Signal-To-Noise Ratio, Image Processing, Computer-Assisted. Cited 6 times so far (Crossref); 60 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Seventh Framework Programme, Bundesministerium für Bildung und Forschung, Deutsche Forschungsgemeinschaft.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To compare MR axon radius estimation in human white matter using a multiband spiral sequence combined with field monitoring to the current state‐of‐the‐art echo‐planar imaging (EPI)‐based approach.

Methods

A custom multiband spiral sequence was used for diffusion‐weighted imaging at ultra‐high ‐values. Field monitoring and higher order image reconstruction were employed to greatly reduce artifacts in spiral images. Diffusion weighting parameters were chosen to match a state‐of‐the art EPI‐based axon radius mapping protocol. The spiral approach was compared to the EPI approach by comparing the image signal‐to‐noise ratio (SNR) and performing a test–retest study to assess the respective variability and repeatability of axon radius mapping. Effective axon radius estimates were compared over white matter voxels and along the left corticospinal tract.

Results

Increased SNR and reduced artifacts in spiral images led to reduced variability in resulting axon radius maps, especially in low‐SNR regions. Test–retest variability was reduced by a factor of approximately 1.5 using the spiral approach. Reduced repeatability due to significant bias was found for some subjects in both spiral and EPI approaches, and attributed to scanner instability, pointing to a previously unknown limitation of the state‐of‐the‐art approach.

Conclusion

Combining spiral readouts with field monitoring improved mapping of the effective axon radius compared to the conventional EPI approach.

Subjects

MeSH terms (MEDLINE)

White MatterAxonsSignal-To-Noise RatioImage Processing, Computer-AssistedHumansAdultReproducibility of ResultsMaleAlgorithmsEcho-Planar ImagingFemaleDiffusion Magnetic Resonance ImagingArtifactsBrain

Author keywords

EPIaxon radiusfield monitoringspiral

Authors and institutions

  • MR Physics, German Center for Neurodegenerative Diseases (DZNE) e.V, Bonn, Germany.
  • Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
  • Clinical Research, German Center for Neurodegenerative Diseases (DZNE) e.V, Bonn, Germany.
  • University of Bonn, Bonn, Germany.
  • Felix Bloch Institute for Solid State Physics, Faculty of Physics and Earth System Sciences, Leipzig University, Leipzig, Germany.
  • Wellcome Centre for Human Neuroimaging, Institute of Neurology, University College London, London, UK.

ORCID profiles: Marten Veldmann, Luke J Edwards, Kerrin J Pine, Philipp Ehses, Mónica Ferreira, Nikolaus Weiskopf, Tony Stoecker

Funding

  • Seventh Framework Programme
  • Bundesministerium für Bildung und Forschung
  • Deutsche Forschungsgemeinschaft
  • Horizon 2020 Framework Programme

Cite

APA

Veldmann, M., Edwards, L. J., Pine, K. J., Ehses, P., Ferreira, M., Weiskopf, N., & Stoecker, T. (2024). Improving MR axon radius estimation in human white matter using spiral acquisition and field monitoring. Magnetic Resonance in Medicine, 92(5), 1898-1912. https://doi.org/10.1002/mrm.30180

Vancouver

Veldmann M, Edwards LJ, Pine KJ, Ehses P, Ferreira M, Weiskopf N, et al. Improving MR axon radius estimation in human white matter using spiral acquisition and field monitoring. Magnetic Resonance in Medicine. 2024;92(5):1898-1912. doi:10.1002/mrm.30180

BibTeX
@article{Veldmann2024,
  author = {Veldmann, Marten and Edwards, Luke J and Pine, Kerrin J and Ehses, Philipp and Ferreira, Mónica and Weiskopf, Nikolaus and Stoecker, Tony},
  title = {Improving MR axon radius estimation in human white matter using spiral acquisition and field monitoring},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  volume = {92},
  number = {5},
  pages = {1898--1912},
  doi = {10.1002/mrm.30180}
}
Start for free →