Multiparametric exchange protons using Z‐spectrum analysis proton (ZAP) and CEST on phantoms and human abdomen
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30140 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2024. Written by Vadim Malis and 1 co-authors. Institution: Department of Radiology, University of California, San Diego, La Jolla, California, USA. Major MEDLINE topics: Phantoms, Imaging, Protons, Magnetic Resonance Imaging, Abdomen. 30 references. Funded by: NIA NIH HHS, Canon Medical Systems Corp., JAPAN.
Abstract (original language)
Purpose
This study aims to investigate a multiparametric exchange proton approach using CEST and Z‐spectrum analysis protons (ZAP) in human abdominal organs, focusing on tissue differentiation for a potential early biomarker of abnormality. Prior to human studies, CEST and ZAP effects were studied in phantoms containing exchange protons.
Methods
Phantoms composed of iopamidol and iohexol solutions with varying pH levels, along with 12 human subjects, were scanned on a clinical 3T MR scanner. Subsequent ZAP analyses employed a two‐Lorentzian pool model to provide free and restricted apparent , and their fractions for data acquired across a wide range of offset frequencies (±100 kHz or ± 800 ppm), while a narrower range (±7 ppm or ± 900 Hz) was used for CEST analysis to estimate magnetization transfer ratio asymmetry (MTR Asym ) for exchange protons like hydroxyl (—OH), amine (—NH 2 ), and amide (—NH), resonating ˜1, 2, and 3.5 ppm, respectively. Differences in ZAP metrics across various organs were statistically analyzed using one‐way analysis of variance (ANOVA).
Results
The phantom study differentiated contrast agents based on resonance peaks detected from CEST analysis, while ZAP metrics showed sensitivity to pH variations. In human, ZAP metrics revealed significant differences in abdominal organs, with a subgroup study indicating changes in ZAP metrics due to the presence of gallstones.
Conclusion
CEST and ZAP techniques demonstrated promise in specific CEST protons and wide range ZAP protons and identifying tissue‐specific characteristics. The preliminary findings underscore the necessity for more extensive study involving a broader subject pool to potentially establish biomarkers for diseased states.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Radiology, University of California, San Diego, La Jolla, California, USA.
ORCID profiles: Vadim Malis, Mitsue Miyazaki
Funding
- NIA NIH HHS
- Canon Medical Systems Corp., JAPAN
Cite
APA
Malis, V., & Miyazaki, M. (2024). Multiparametric exchange protons using Z‐spectrum analysis proton (ZAP) and CEST on phantoms and human abdomen. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30140
Vancouver
Malis V, Miyazaki M. Multiparametric exchange protons using Z‐spectrum analysis proton (ZAP) and CEST on phantoms and human abdomen. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30140
BibTeX
@article{Malis2024,
author = {Malis, Vadim and Miyazaki, Mitsue},
title = {Multiparametric exchange protons using Z‐spectrum analysis proton (ZAP) and CEST on phantoms and human abdomen},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30140}
}
EUVIMED