Improved quantification in CEST‐MRI by joint spatial total generalized variation
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30129 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2024. Written by Markus Huemer and 8 co-authors. Institution: Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria. Major MEDLINE topics: Algorithms, Phantoms, Imaging, Magnetic Resonance Imaging, Signal-To-Noise Ratio. Cited 2 times so far (Crossref); 41 references. The full text is freely available (open access, CC BY 4.0). Funded by: Austrian Science Fund.
Abstract (original language)
Purpose
In this work, the use of joint Total Generalized Variation (TGV) regularization to improve Multipool‐Lorentzian fitting of chemical exchange saturation transfer (CEST) Spectra in terms of stability and parameter signal‐to‐noise ratio (SNR) was investigated. Theory and Methods The joint TGV term was integrated into the nonlinear parameter fitting problem. To increase convergence and weight the gradients, preconditioning using a voxel‐wise singular value decomposition was applied to the problem, which was then solved using the iteratively regularized Gauss–Newton method combined with a Primal‐Dual splitting algorithm. The TGV method was evaluated on simulated numerical phantoms, 3T phantom data and 7T in vivo data with respect to systematic errors and robustness. Three reference methods were also implemented: The standard nonlinear fitting, a method using a nonlocal‐means filter for denoising and the pyramid scheme, which uses downsampled images to acquire accurate start values.
Results
The proposed regularized fitting method showed significantly improved robustness (compared to the reference methods). In testing, over a range of SNR values the TGV fit outperformed the other methods and showed accurate results even for large amounts of added noise. Parameter values found were closer or comparable to the ground truth. For in vivo datasets, the added regularization increased the parameter map SNR and prevented instabilities.
Conclusion
The proposed fitting method using TGV regularization leads to improved results over a range of different data‐sets and noise levels. Furthermore, it can be applied to all Z‐spectrum data, with different amounts of pools, where the improved SNR and stability can increase diagnostic confidence.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria.
- Institute of Neuroradiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany.
- Department of Mathematics and Scientific Computing, University of Graz, Graz, Austria.
- BioTechMed Graz, Graz, Austria.
- High-Field Magnetic Resonance Center, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.
- Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
ORCID profiles: Markus Huemer, Oliver Maier, Moritz Simon Fabian, Kristian Bredies, Moritz Zaiss, Rudolf Stollberger
Funding
- Austrian Science Fund
Cite
APA
Huemer, M., Stilianu, C., Maier, O., Fabian, M. S., Schmidt, M., Doerfler, A., Bredies, K., Zaiss, M., & Stollberger, R. (2024). Improved quantification in CEST‐MRI by joint spatial total generalized variation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30129
Vancouver
Huemer M, Stilianu C, Maier O, Fabian MS, Schmidt M, Doerfler A, et al. Improved quantification in CEST‐MRI by joint spatial total generalized variation. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30129
BibTeX
@article{Huemer2024,
author = {Huemer, Markus and Stilianu, Clemens and Maier, Oliver and Fabian, Moritz Simon and Schmidt, Manuel and Doerfler, Arnd and Bredies, Kristian and Zaiss, Moritz and Stollberger, Rudolf},
title = {Improved quantification in CEST‐MRI by joint spatial total generalized variation},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30129}
}