EUVIMEDEUVIMED entdecken
Open Access

Eddy current‐induced artifact correction in high b‐value ex vivo human brain diffusion MRI with dynamic field monitoring

Gabriel Ramos-Llordén iD, Daniel J Park, John E Kirsch, Alina Scholz iD, Boris Keil iD, Chiara Maffei, Hong-Hsi Lee iD, Berkin Bilgic iD, Brian L Edlow, Choukri Mekkaoui, Anastasia Yendiki, Thomas Witzel und 1 weitere

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29873 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Gabriel Ramos-Llordén und 12 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Artifacts. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate whether spatiotemporal magnetic field monitoring can correct pronounced eddy current‐induced artifacts incurred by strong diffusion‐sensitizing gradients up to 300 mT/m used in high b‐value diffusion‐weighted (DW) EPI.

Methods

A dynamic field camera equipped with 16 1 H NMR field probes was first used to characterize field perturbations caused by residual eddy currents from diffusion gradients waveforms in a 3D multi‐shot EPI sequence on a 3T Connectom scanner for different gradient strengths (up to 300 mT/m), diffusion directions, and shots. The efficacy of dynamic field monitoring‐based image reconstruction was demonstrated on high‐gradient strength, submillimeter resolution whole‐brain ex vivo diffusion MRI. A 3D multi‐shot image reconstruction framework was developed that incorporated the nonlinear phase evolution measured with the dynamic field camera.

Results

Phase perturbations in the readout induced by residual eddy currents from strong diffusion gradients are highly nonlinear in space and time, vary among diffusion directions, and interfere significantly with the image encoding gradients, changing the k‐space trajectory. During the readout, phase modulations between odd and even EPI echoes become non‐static and diffusion encoding direction‐dependent. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting reduction approaches such as navigator‐ and structured low‐rank‐based methods or MUSE followed by image‐based distortion correction with the FSL tool “eddy.” Conclusion Strong eddy current artifacts characteristic of high‐gradient strength DW‐EPI can be well corrected with dynamic field monitoring‐based image reconstruction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedArtifactsHumansDiffusion Magnetic Resonance ImagingBrainImaging, Three-DimensionalEcho-Planar Imaging

Stichwörter der Autor:innen

dynamic field monitoringeddyeddy currentsex-vivo diffusion MRIgeometric distortionsghostinghigh-gradient strength diffusion MRI

Autor:innen und Institutionen

  • Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
  • Institute of Medical Physics and Radiation Protection, Mittelhessen University of Applied Sciences, Giessen, Germany.
  • Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Philipps University of Marburg, Marburg, Germany.
  • Center for Neurotechnology and Neurorecovery, Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Q Bio Inc, San Carlos, California, USA.
  • Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.

ORCID-Profile: Gabriel Ramos-Llordén, Alina Scholz, Boris Keil, Hong-Hsi Lee, Berkin Bilgic, Susie Y Huang

Förderung

  • NHLBI NIH HHS
  • NIH HHS
  • NIBIB NIH HHS
  • NINDS NIH HHS
  • United States Department of Defense
  • James S. McDonnell Foundation
  • National Institutes of Health
  • U.S. Department of Defense

Zitieren

APA

Ramos-Llordén, G., Park, D. J., Kirsch, J. E., Scholz, A., Keil, B., Maffei, C., Lee, H. H., Bilgic, B., Edlow, B. L., Mekkaoui, C., Yendiki, A., Witzel, T., & Huang, S. Y. (2024). Eddy current‐induced artifact correction in high b‐value ex vivo human brain diffusion MRI with dynamic field monitoring. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29873

Vancouver

Ramos-Llordén G, Park DJ, Kirsch JE, Scholz A, Keil B, Maffei C, et al. Eddy current‐induced artifact correction in high b‐value ex vivo human brain diffusion MRI with dynamic field monitoring. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29873

BibTeX
@article{RamosLlordn2024,
  author = {Ramos-Llordén, Gabriel and Park, Daniel J and Kirsch, John E and Scholz, Alina and Keil, Boris and Maffei, Chiara and Lee, Hong-Hsi and Bilgic, Berkin and Edlow, Brian L and Mekkaoui, Choukri and Yendiki, Anastasia and Witzel, Thomas and Huang, Susie Y},
  title = {Eddy current‐induced artifact correction in high b‐value ex vivo human brain diffusion MRI with dynamic field monitoring},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29873}
}
Kostenlos starten →