EUVIMEDDescubrir EUVIMED
Open access · CC BY 4.0

Bayesian optimization of gradient trajectory for parallel‐transmit pulse design

Minghao Zhang iD, Christopher T Rodgers iD

Magnetic Resonance in Medicine · 2024-06 · 91 (6) · 2358-2373

DOI: 10.1002/mrm.30007 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2024-01-09. Written by Minghao Zhang and 1 co-authors. Institution: Wolfson Brain Imaging Center, University of Cambridge, Cambridge, UK. Major MEDLINE topics: Magnetic Resonance Imaging, Algorithms. Cited 3 times so far (Crossref); 43 references. The full text is freely available (open access, CC BY 4.0). Funded by: Medical Research Council, NIHR Cambridge Biomedical Research Centre, Siemens.

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Purpose

Spoke pulses improve excitation homogeneity in parallel‐transmit MRI. We propose an efficient global optimization algorithm, Bayesian optimization of gradient trajectory (BOGAT), for single‐slice and simultaneous multislice imaging. Theory and Methods BOGAT adds an outer loop to optimize k T ‐space positions. For each position, the RF coefficients are optimized (e.g., with magnitude least squares) and the cost function evaluated. Bayesian optimization progressively estimates the cost function. It automatically chooses the k T ‐space positions to sample, to achieve fast convergence, often coming close to the globally optimal spoke positions. We investigated the typical features of spokes cost functions by a grid search with field maps comprising 85 slabs from 14 volunteers. We tested BOGAT in this database, and prospectively in a phantom and in vivo. We compared the vendor‐provided Fourier transform approach with the same magnitude least squares RF optimizer.

Results

The cost function is nonconvex and seen empirically to be piecewise smooth with discontinuities where the underlying RF optimum changes sharply. BOGAT converged to within 10% of the global minimum cost within 30 iterations in 93% of slices in our database. BOGAT achieved up to 56% lower flip angle RMS error (RMSE) or 55% lower pulse energy in phantoms versus the Fourier transform approach, and up to 30% lower RMSE and 29% lower energy in vivo with 7.8 s extra computation.

Conclusion

BOGAT efficiently estimated near‐global optimum spoke positions for the two‐spoke tests, reducing flip‐angle RMSE and/or pulse energy in a computation time (˜10 s), which is suitable for online optimization.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingAlgorithmsHumansBayes TheoremPhantoms, ImagingLeast-Squares AnalysisBrain

Author keywords

7 TBayesian optimizationparallel transmitpulse designspokesultrahigh field

Authors and institutions

  • Wolfson Brain Imaging Center, University of Cambridge, Cambridge, UK.

ORCID profiles: Minghao Zhang, Christopher T Rodgers

Funding

  • Medical Research Council
  • NIHR Cambridge Biomedical Research Centre
  • Siemens
  • Medical Research Council Canada
  • Cambridge Trust

Cite

APA

Zhang, M., & Rodgers, C. T. (2024). Bayesian optimization of gradient trajectory for parallel‐transmit pulse design. Magnetic Resonance in Medicine, 91(6), 2358-2373. https://doi.org/10.1002/mrm.30007

Vancouver

Zhang M, Rodgers CT. Bayesian optimization of gradient trajectory for parallel‐transmit pulse design. Magnetic Resonance in Medicine. 2024;91(6):2358-2373. doi:10.1002/mrm.30007

BibTeX
@article{Zhang2024,
  author = {Zhang, Minghao and Rodgers, Christopher T},
  title = {Bayesian optimization of gradient trajectory for parallel‐transmit pulse design},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  volume = {91},
  number = {6},
  pages = {2358--2373},
  doi = {10.1002/mrm.30007}
}
Start for free →