EUVIMEDOpdag EUVIMED
Open access · CC BY-NC 4.0

Optimizing background suppression for dual‐module velocity‐selective arterial spin labeling: Without using additional background‐suppression pulses

Jia Guo iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29995 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Jia Guo. Institution: Department of Bioengineering, University of California Riverside, Riverside, California, USA. Major MEDLINE topics: Magnetic Resonance Angiography, White Matter. Cited 7 times so far (Crossref); 20 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: NCI NIH HHS, NIBIB NIH HHS, NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Background suppression (BS) is recommended in arterial spin labeling (ASL) for improved SNR but is difficult to optimize in existing velocity‐selective ASL (VSASL) methods. Dual‐module VSASL (dm‐VSASL) enables delay‐insensitive, robust, and SNR‐efficient perfusion imaging, while allowing efficient BS, but its optimization has yet to be thoroughly investigated.

Methods

The inversion effects of the velocity‐selective labeling pulses, such as velocity‐selective inversion (VSI), can be used for BS, and were modeled for optimizing BS in dm‐VSASL. In vivo experiments using dual‐module VSI (dm‐VSI) were performed to compare two BS strategies: a conventional one with additional BS pulses and a new one without any BS pulse. Their BS performance, temporal noise, and temporal SNR were examined and compared, with pulsed and pseudo‐continuous ASL (PASL and PCASL) as the reference.

Results

The in vivo experiments validated the BS modeling. Strong positive linear correlations ( r > 0.82, p < 0.0001) between the temporal noise and the tissue signal were found in PASL/PCASL and dm‐VSI. Optimal BS can be achieved with and without additional BS pulses in dm‐VSI; the latter improved the ASL signals by 8.5% in gray matter ( p = 0.006) and 12.2% in white matter ( p = 0.014) and tended to provide better temporal SNR. The dm‐VSI measured significantly higher ASL signal ( p < 0.016) and temporal SNR ( p < 0.018) than PASL and PCASL. Complex reconstruction was found necessary with aggressive BS.

Conclusion

Guided by modeling, optimal BS can be achieved without any BS pulse in dm‐VSASL, further improving the ASL signal and the SNR performance.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance AngiographyWhite MatterSpin LabelsArteriesGray MatterCerebrovascular CirculationBrain

Author keywords

SNRarterial spin labelingbackground suppressiondual‐module VSASLvelocity‐selective arterial spin labelingvelocity‐selective inversion

Substances

Spin Labels

Authors and institutions

  • Department of Bioengineering, University of California Riverside, Riverside, California, USA.

ORCID profiles: Jia Guo

Funding

  • NCI NIH HHS
  • NIBIB NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Guo, J. (2024). Optimizing background suppression for dual‐module velocity‐selective arterial spin labeling: Without using additional background‐suppression pulses. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29995

Vancouver

Guo J. Optimizing background suppression for dual‐module velocity‐selective arterial spin labeling: Without using additional background‐suppression pulses. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29995

BibTeX
@article{Guo2024,
  author = {Guo, Jia},
  title = {Optimizing background suppression for dual‐module velocity‐selective arterial spin labeling: Without using additional background‐suppression pulses},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29995}
}
Start for free →