EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic B 0 field shimming for improving pseudo‐continuous arterial spin labeling at 7 T

Yang Ji iD, Joseph G Woods iD, Hongwei Li iD, Thomas W Okell iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30387 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Yang Ji und 3 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Brain, Image Processing, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

B 0 field inhomogeneity within the brain‐feeding arteries is a major issue for pseudo‐continuous arterial spin labeling (PCASL) at 7 T because it reduces the labeling efficiency and leads to a loss of perfusion signal. This study aimed to develop a vessel‐specific dynamic B 0 field shimming method for 7 T PCASL to improve the labeling efficiency by correcting off‐resonance within the arteries in the labeling region.

Methods

We implemented a PCASL sequence with dynamic B 0 shimming at 7 T that compensates for B 0 field offsets in the brain‐feeding arteries by updating linear shimming terms and adding a phase increment to the PCASL RF pulses. Rapidly acquired vessel‐specific B 0 field maps were used to calculate dynamic B 0 shimming parameters. We evaluated both 2D and 3D variants of our method, comparing their performance against the established global frequency offset and optimal encoding scheme‐based corrections. Cerebral blood flow (CBF) maps were quantified before and after corrections, and CBF values from different methods were compared across the whole brain, white matter, and gray matter regions.

Results

All off‐resonance correction methods significantly recovered perfusion signals across the brain. The proposed vessel‐specific dynamic B 0 shimming method improved the labeling efficiency while maintaining optimal static shimming in the imaging region. Perfusion‐weighted images demonstrated the superiority of the 3D dynamic B 0 shimming method compared to global or 2D‐based correction approaches. CBF analysis revealed that 3D dynamic B 0 shimming significantly increased CBF values relative to the other methods.

Conclusion

Our proposed dynamic B 0 shimming method offers a significant advancement in PCASL robustness and effectiveness, enabling full utilization of 7 T ASL high sensitivity and spatial resolution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainImage Processing, Computer-AssistedMagnetic Resonance ImagingHumansSpin LabelsCerebrovascular CirculationMaleAdultAlgorithmsFemaleGray MatterWhite MatterArteries

Stichwörter der Autor:innen

7 TB0 inhomogeneitydynamic B0 field shimmingpseudo‐continuous arterial spin labeling (PCASL)

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
  • Department of Electronic Engineering and Information Science, School of Information Science and Technology, University of Science and Technology of China, Hefei, People's Republic of China.
  • Institute of Science and Technology for Brain-inspired Intelligence, Fudan University, Shanghai, People's Republic of China.

ORCID-Profile: Yang Ji, Joseph G Woods, Hongwei Li, Thomas W Okell

Förderung

  • Wellcome Trust
  • National Natural Science Foundation of China

Zitieren

APA

Ji, Y., Woods, J. G., Li, H., & Okell, T. W. (2025). Dynamic B 0 field shimming for improving pseudo‐continuous arterial spin labeling at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30387

Vancouver

Ji Y, Woods JG, Li H, Okell TW. Dynamic B 0 field shimming for improving pseudo‐continuous arterial spin labeling at 7 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30387

BibTeX
@article{Ji2025,
  author = {Ji, Yang and Woods, Joseph G and Li, Hongwei and Okell, Thomas W},
  title = {Dynamic B 0 field shimming for improving pseudo‐continuous arterial spin labeling at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30387}
}
Kostenlos starten →