EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of distortion correction preprocessing pipelines for DTI in the upper limb

Ryckie G Wade iD, Winnie Tam iD, Antonia Perumal iD, Sophanit Pepple iD, Timothy T Griffiths iD, Robert Flather iD, Hamied A Haroon iD, David Shelley, Sven Plein iD, Grainne Bourke iD, Irvin Teh iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29881 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Ryckie G Wade und 10 weiteren Autor:innen. Beteiligte Einrichtung: Leeds Institute for Medical Research, University of Leeds, Leeds, UK. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Diffusion Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Arthritis Research UK, British Heart Foundation, Medical Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

DTI characterizes tissue microstructure and provides proxy measures of nerve health. Echo‐planar imaging is a popular method of acquiring DTI but is susceptible to various artifacts (e.g., susceptibility, motion, and eddy currents), which may be ameliorated via preprocessing. There are many pipelines available but limited data comparing their performance, which provides the rationale for this study.

Methods

DTI was acquired from the upper limb of heathy volunteers at 3T in blip‐up and blip‐down directions. Data were independently corrected using (i) FSL's TOPUP & eddy, (ii) FSL's TOPUP, (iii) DSI Studio, and (iv) TORTOISE. DTI metrics were extracted from the median, radial, and ulnar nerves and compared (between pipelines) using mixed‐effects linear regression. The geometric similarity of corrected b = 0 images and the slice matched T1‐weighted (T1w) images were computed using the Sörenson‐Dice coefficient.

Results

Without preprocessing, the similarity coefficient of the blip‐up and blip‐down datasets to the T1w was 0·80 and 0·79, respectively. Preprocessing improved the geometric similarity by 1% with no difference between pipelines. Compared to TOPUP & eddy, DSI Studio and TORTOISE generated 2% and 6% lower estimates of fractional anisotropy, and 6% and 13% higher estimates of radial diffusivity, respectively. Estimates of anisotropy from TOPUP & eddy versus TOPUP were not different but TOPUP reduced radial diffusivity by 3%. The agreement of DTI metrics between pipelines was poor.

Conclusions

Preprocessing DTI from the upper limb improves geometric similarity but the choice of the pipeline introduces clinically important variability in diffusion parameter estimates from peripheral nerves.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Tensor ImagingDiffusion Magnetic Resonance ImagingHumansPeripheral NervesUpper ExtremityEcho-Planar ImagingImage Processing, Computer-Assisted

Stichwörter der Autor:innen

DTIanisotropydiffusiondiffusivitydistortionmagnetic resonancemediannervepre-processingradialulnar

Autor:innen und Institutionen

  • Leeds Institute for Medical Research, University of Leeds, Leeds, UK.
  • Department of Plastic, Reconstructive and Hand Surgery, Leeds Teaching Hospitals Trust, Leeds, UK.
  • Division of Psychology, Communication & Human Neuroscience, The University of Manchester, Manchester, UK.
  • Leeds Teaching Hospitals Trust, Leeds, UK.
  • Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.

ORCID-Profile: Ryckie G Wade, Winnie Tam, Antonia Perumal, Sophanit Pepple, Timothy T Griffiths, Robert Flather, Hamied A Haroon, Sven Plein, Grainne Bourke, Irvin Teh

Förderung

  • Arthritis Research UK
  • British Heart Foundation
  • Medical Research Council
  • Department of Health and Social Care
  • Medical Research Council Canada
  • National Institute for Health and Care Research
  • Leeds Biomedical Research Centre

Zitieren

APA

Wade, R. G., Tam, W., Perumal, A., Pepple, S., Griffiths, T. T., Flather, R., Haroon, H. A., Shelley, D., Plein, S., Bourke, G., & Teh, I. (2024). Comparison of distortion correction preprocessing pipelines for DTI in the upper limb. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29881

Vancouver

Wade RG, Tam W, Perumal A, Pepple S, Griffiths TT, Flather R, et al. Comparison of distortion correction preprocessing pipelines for DTI in the upper limb. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29881

BibTeX
@article{Wade2024,
  author = {Wade, Ryckie G and Tam, Winnie and Perumal, Antonia and Pepple, Sophanit and Griffiths, Timothy T and Flather, Robert and Haroon, Hamied A and Shelley, David and Plein, Sven and Bourke, Grainne and Teh, Irvin},
  title = {Comparison of distortion correction preprocessing pipelines for DTI in the upper limb},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29881}
}
Kostenlos starten →