EUVIMEDEUVIMED entdecken
Crossref

Comparison of uniform‐density, variable‐density, and dual‐density spiral samplings for multi‐shot DWI

Guangqi Li, Xiaodong Ma iD, Sisi Li iD, Xinyu Ye, Peter Börnert, Xiaohong Joe Zhou, Hua Guo iD

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29633 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Guangqi Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Algorithms, Diffusion Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 82 Literaturangaben. Gefördert von: Natural Science Foundation of Beijing Municipality, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the performances of uniform‐density spiral (UDS), variable‐density spiral (VDS), and dual‐density spiral (DDS) samplings in multi‐shot diffusion imaging, and determine a sampling strategy that balances reliability of shot navigator and overall DWI image quality. Theory and Methods UDS, VDS, and DDS trajectories were implemented to achieve four‐shot diffusion‐weighted spiral imaging. First, the static B0 off‐resonance effects in UDS, VDS, and DDS acquisitions were analyzed based on a signal model. Then, in vivo experiments were performed to verify the theoretical analyses, and fractional anisotropy (FA) fitting residuals were used to quantitatively assess the quality of spiral diffusion data for tensor estimation. Finally, the SNR performances and g‐factor behavior of the three spiral samplings were evaluated using a Monte Carlo‐based pseudo multiple replica method.

Results

Among the three spiral trajectories with the same readout duration, UDS sampling exhibited the least off‐resonance artifacts. This was most evident when the static B0 off‐resonance effect was severe. The UDS diffusion images had higher anatomical fidelity and lower FA fitting residuals than the other two counterparts. Furthermore, the four‐shot UDS acquisition achieved the best SNR performance in diffusion imaging with 12.11% and 40.85% improvements over the VDS and DDS acquisitions with the same readout duration, respectively.

Conclusion

UDS sampling is an efficient spiral acquisition scheme for high‐resolution diffusion imaging with reliable navigator information. It provides superior off‐resonance performance and SNR efficiency over the VDS and DDS samplings for the tested scenarios.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsDiffusion Magnetic Resonance ImagingReproducibility of ResultsDiffusion Tensor ImagingImage Interpretation, Computer-AssistedArtifactsImage Processing, Computer-AssistedEcho-Planar Imaging

Stichwörter der Autor:innen

diffusion imagingg-factoroff-resonancesignal-to-noise ratiospiral sampling

Autor:innen und Institutionen

  • Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China.
  • Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.
  • Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands.
  • Philips Research, Hamburg, Germany.
  • Center for MR Research and Departments of Radiology, Neurosurgery, and Biomedical Engineering, University of Illinois College of Medicine at Chicago, Chicago, Illinois, USA.

ORCID-Profile: Xiaodong Ma, Sisi Li, Hua Guo

Förderung

  • Natural Science Foundation of Beijing Municipality
  • National Natural Science Foundation of China

Zitieren

APA

Li, G., Ma, X., Li, S., Ye, X., Börnert, P., Zhou, X. J., & Guo, H. (2023). Comparison of uniform‐density, variable‐density, and dual‐density spiral samplings for multi‐shot DWI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29633

Vancouver

Li G, Ma X, Li S, Ye X, Börnert P, Zhou XJ, et al. Comparison of uniform‐density, variable‐density, and dual‐density spiral samplings for multi‐shot DWI. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29633

BibTeX
@article{Li2023,
  author = {Li, Guangqi and Ma, Xiaodong and Li, Sisi and Ye, Xinyu and Börnert, Peter and Zhou, Xiaohong Joe and Guo, Hua},
  title = {Comparison of uniform‐density, variable‐density, and dual‐density spiral samplings for multi‐shot DWI},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29633}
}
Kostenlos starten →