EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

FD‐Net: An unsupervised deep forward‐distortion model for susceptibility artifact correction in EPI

Abdallah Zaid Alkilani iD, Tolga Çukur iD, Emine Ulku Saritas iD

Magnetic Resonance in Medicine · 2024-01 · 91 (1) · 280-296

DOI: 10.1002/mrm.29851 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 09.10.2023. Verfasst von Abdallah Zaid Alkilani und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Brain. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific and Technological Research Council of Turkey.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To introduce an unsupervised deep‐learning method for fast and effective correction of susceptibility artifacts in reversed phase‐encode (PE) image pairs acquired with echo planar imaging (EPI).

Methods

Recent learning‐based correction approaches in EPI estimate a displacement field, unwarp the reversed‐PE image pair with the estimated field, and average the unwarped pair to yield a corrected image. Unsupervised learning in these unwarping‐based methods is commonly attained via a similarity constraint between the unwarped images in reversed‐PE directions, neglecting consistency to the acquired EPI images. This work introduces a novel unsupervised deep Forward‐Distortion Network (FD‐Net) that predicts both the susceptibility‐induced displacement field and the underlying anatomically correct image. Unlike previous methods, FD‐Net enforces the forward‐distortions of the correct image in both PE directions to be consistent with the acquired reversed‐PE image pair. FD‐Net further leverages a multiresolution architecture to maintain high local and global performance.

Results

FD‐Net performs competitively with a gold‐standard reference method (TOPUP) in image quality, while enabling a leap in computational efficiency. Furthermore, FD‐Net outperforms recent unwarping‐based methods for unsupervised correction in terms of both image and field quality.

Conclusion

The unsupervised FD‐Net method introduces a deep forward‐distortion approach to enable fast, high‐fidelity correction of susceptibility artifacts in EPI by maintaining consistency to measured data. Therefore, it holds great promise for improving the anatomical accuracy of EPI imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingBrainArtifactsAlgorithmsImage Processing, Computer-Assisted

Stichwörter der Autor:innen

deep learningecho planar imagingreversed phase-encodingsusceptibility artifactsunsupervised learning

Autor:innen und Institutionen

  • Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.
  • National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.
  • Neuroscience Graduate Program, Bilkent University, Ankara, Turkey.

ORCID-Profile: Abdallah Zaid Alkilani, Tolga Çukur, Emine Ulku Saritas

Förderung

  • Scientific and Technological Research Council of Turkey

Zitieren

APA

Zaid Alkilani, A., Çukur, T., & Saritas, E. U. (2024). FD‐Net: An unsupervised deep forward‐distortion model for susceptibility artifact correction in EPI. Magnetic Resonance in Medicine, 91(1), 280-296. https://doi.org/10.1002/mrm.29851

Vancouver

Zaid Alkilani A, Çukur T, Saritas EU. FD‐Net: An unsupervised deep forward‐distortion model for susceptibility artifact correction in EPI. Magnetic Resonance in Medicine. 2024;91(1):280-296. doi:10.1002/mrm.29851

BibTeX
@article{ZaidAlkilani2024,
  author = {Zaid Alkilani, Abdallah and Çukur, Tolga and Saritas, Emine Ulku},
  title = {FD‐Net: An unsupervised deep forward‐distortion model for susceptibility artifact correction in EPI},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  volume = {91},
  number = {1},
  pages = {280--296},
  doi = {10.1002/mrm.29851}
}