Rapid T2∗‐weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department
Magnetic Resonance in Medicine · 2023
DOI: 10.1002/mrm.29809 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2023. Written by Zhiqiang Li and 3 co-authors. Institution: Department of Neuroradiology, Barrow Neurological Institute, Phoenix, Arizona, USA. Major MEDLINE topics: Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging. 37 references. Funded by: Barrow Neurological Foundation.
Abstract (original language)
Purpose
Brain MRI is increasingly used in the emergency department (ED), where ‐weighted MRI is an essential tool for detecting hemorrhage and stroke. The goal of this study was to develop a rapid ‐weighted MRI technique capable of correcting motion‐induced artifacts, thereby simultaneously improving scan time and motion robustness for ED applications.
Methods
A 2D gradient‐echo (GRE)–based multishot EPI (msEPI) technique was implemented using a navigator echo for estimating motion‐induced errors. Bulk rigid head motion and phase errors were retrospectively corrected using an iterative conjugate gradient approach in the reconstruction pipeline. Three volunteers and select patients were imaged at 3 T and/or 1.5 T with an approximately 1‐min full‐brain protocol using the proposed msEPI technique and compared to an approximately 3‐min standard‐of‐care GRE protocol to examine its performance.
Results
Data from volunteers demonstrated that in‐plane motion artifacts could be effectively corrected with the proposed msEPI technique, and through‐plane motion artifacts could be mitigated. Patient images were qualitatively reviewed by one radiologist without a formal statistical analysis. These results suggested the proposed technique could correct motion‐induced artifacts in the clinical setting. In addition, the conspicuity of susceptibility‐related lesions using the proposed msEPI technique was comparable, or improved, compared to GRE.
Conclusion
A 1‐min full‐brain ‐weighted MRI technique was developed using msEPI with a navigator echo to correct motion‐induced errors. Preliminary clinical results suggest faster scans and improved motion robustness and lesion conspicuity make msEPI a competitive alternative to traditional ‐weighted MRI techniques for brain studies in the ED.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Neuroradiology, Barrow Neurological Institute, Phoenix, Arizona, USA.
- Philips Healthcare, Houston, Texas, USA.
ORCID profiles: Zhiqiang Li
Funding
- Barrow Neurological Foundation
Cite
APA
Li, Z., Ooi, M. B., Murchison, J. A., & Karis, J. P. (2023). Rapid T2∗‐weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29809
Vancouver
Li Z, Ooi MB, Murchison JA, Karis JP. Rapid T2∗‐weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29809
BibTeX
@article{Li2023,
author = {Li, Zhiqiang and Ooi, Melvyn B and Murchison, James A and Karis, John P},
title = {Rapid T2∗‐weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department},
journal = {Magnetic Resonance in Medicine},
year = {2023},
doi = {10.1002/mrm.29809}
}
EUVIMED