EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Retrospective frequency drift correction of rosette MRSI data using spectral registration

Sneha Senthil iD, Brenden Kadota, Peter Truong, Jamie Near iD

Magnetic Resonance in Medicine · 2023-10 · 90 (4) · 1271-1281

DOI: 10.1002/mrm.29760 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 18.06.2023. Verfasst von Sneha Senthil und 3 weiteren Autor:innen. Beteiligte Einrichtung: Integrated Program in Neuroscience, McGill University, Montreal, Quebec, Canada. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CIHR, Canadian Institutes of Health Research, Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Frequency drift correction is an important postprocessing step in MRS that yields improvements in spectral quality and metabolite quantification. Although routinely applied in single‐voxel MRS, drift correction is much more challenging in MRSI due to the presence of phase‐encoding gradients. Thus, separately acquired navigator scans are normally required for drift estimation. In this work, we demonstrate the use of self‐navigating rosette MRSI trajectories combined with time‐domain spectral registration to enable retrospective frequency drift corrections without the need for separately acquired navigator echoes.

Methods

A rosette MRSI sequence was implemented to acquire data from the brains of 5 healthy volunteers. FIDs from the center of k‐space ( FIDs) were isolated from each shot of the rosette acquisition, and time‐domain spectral registration was used to estimate the frequency offset of each FID relative to a reference scan (the first FID in the series). The estimated frequency offsets were then used to apply corrections throughout ‐space. Improvements in spectral quality were assessed before and after drift correction.

Results

Spectral registration resulted in significant improvements in signal‐to‐noise ratio (12.9%) and spectral linewidths (18.5%). Metabolite quantification was performed using LCModel, and the average Cramer‐Rao lower bounds uncertainty estimates were reduced by 5.0% for all metabolites, following field drift correction.

Conclusion

This study demonstrated the use of self‐navigating rosette MRSI trajectories to retrospectively correct frequency drift errors in in vivo MRSI data. This correction yields meaningful improvements in spectral quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainMagnetic Resonance ImagingHumansMagnetic Resonance SpectroscopyRetrospective StudiesSignal-To-Noise RatioHealthy Volunteers

Stichwörter der Autor:innen

3TMRSIfrequency drift correction

Autor:innen und Institutionen

  • Integrated Program in Neuroscience, McGill University, Montreal, Quebec, Canada.
  • Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
  • Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.

ORCID-Profile: Sneha Senthil, Jamie Near

Förderung

  • CIHR
  • Canadian Institutes of Health Research
  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Senthil, S., Kadota, B., Truong, P., & Near, J. (2023). Retrospective frequency drift correction of rosette MRSI data using spectral registration. Magnetic Resonance in Medicine, 90(4), 1271-1281. https://doi.org/10.1002/mrm.29760

Vancouver

Senthil S, Kadota B, Truong P, Near J. Retrospective frequency drift correction of rosette MRSI data using spectral registration. Magnetic Resonance in Medicine. 2023;90(4):1271-1281. doi:10.1002/mrm.29760

BibTeX
@article{Senthil2023,
  author = {Senthil, Sneha and Kadota, Brenden and Truong, Peter and Near, Jamie},
  title = {Retrospective frequency drift correction of rosette MRSI data using spectral registration},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  volume = {90},
  number = {4},
  pages = {1271--1281},
  doi = {10.1002/mrm.29760}
}
Kostenlos starten →