Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high‐resolution 3D diffusion MRI
Magnetic Resonance in Medicine · 2023
DOI: 10.1002/mrm.29741 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Ziyu Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Royal Academy of Engineering.
Abstract (Originalsprache)
Purpose
To develop a new method for high‐fidelity, high‐resolution 3D multi‐slab diffusion MRI with minimal distortion and boundary slice aliasing.
Methods
Our method modifies 3D multi‐slab imaging to integrate blip‐reversed acquisitions for distortion correction and oversampling in the slice direction (k z ) for reducing boundary slice aliasing. Our aim is to achieve robust acceleration to keep the scan time the same as conventional 3D multi‐slab acquisitions, in which data are acquired with a single direction of blip traversal and without k z ‐oversampling. We employ a two‐stage reconstruction. In the first stage, the blip‐up/down images are respectively reconstructed and analyzed to produce a field map for each diffusion direction. In the second stage, the blip‐reversed data and the field map are incorporated into a joint reconstruction to produce images that are corrected for distortion and boundary slice aliasing.
Results
We conducted experiments at 7T in six healthy subjects. Stage 1 reconstruction produces images from highly under‐sampled data ( R = 7.2) with sufficient quality to provide accurate field map estimation. Stage 2 joint reconstruction substantially reduces distortion artifacts with comparable quality to fully‐sampled blip‐reversed results (2.4× scan time). Whole‐brain in‐vivo results acquired at 1.22 mm and 1.05 mm isotropic resolutions demonstrate improved anatomical fidelity compared to conventional 3D multi‐slab imaging. Data demonstrate good reliability and reproducibility of the proposed method over multiple subjects.
Conclusion
The proposed acquisition and reconstruction framework provide major reductions in distortion and boundary slice aliasing for 3D multi‐slab diffusion MRI without increasing the scan time, which can potentially produce high‐quality, high‐resolution diffusion MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
ORCID-Profile: Ziyu Li, Wenchuan Wu
Förderung
- Wellcome Trust
- Royal Academy of Engineering
Zitieren
APA
Li, Z., Miller, K. L., Andersson, J. L. R., Zhang, J., Liu, S., Guo, H., & Wu, W. (2023). Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high‐resolution 3D diffusion MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29741
Vancouver
Li Z, Miller KL, Andersson JLR, Zhang J, Liu S, Guo H, et al. Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high‐resolution 3D diffusion MRI. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29741
BibTeX
@article{Li2023,
author = {Li, Ziyu and Miller, Karla L and Andersson, Jesper L R and Zhang, Jieying and Liu, Simin and Guo, Hua and Wu, Wenchuan},
title = {Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high‐resolution 3D diffusion MRI},
journal = {Magnetic Resonance in Medicine},
year = {2023},
doi = {10.1002/mrm.29741}
}
EUVIMED