Comparison of uniform‐density, variable‐density, and dual‐density spiral samplings for multi‐shot DWI
Magnetic Resonance in Medicine · 2023
DOI: 10.1002/mrm.29633 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2023. Written by Guangqi Li and 6 co-authors. Institution: Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China. Major MEDLINE topics: Algorithms, Diffusion Magnetic Resonance Imaging. Cited 3 times so far (Crossref); 82 references. Funded by: Natural Science Foundation of Beijing Municipality, National Natural Science Foundation of China.
Abstract (original language)
Purpose
To compare the performances of uniform‐density spiral (UDS), variable‐density spiral (VDS), and dual‐density spiral (DDS) samplings in multi‐shot diffusion imaging, and determine a sampling strategy that balances reliability of shot navigator and overall DWI image quality. Theory and Methods UDS, VDS, and DDS trajectories were implemented to achieve four‐shot diffusion‐weighted spiral imaging. First, the static B0 off‐resonance effects in UDS, VDS, and DDS acquisitions were analyzed based on a signal model. Then, in vivo experiments were performed to verify the theoretical analyses, and fractional anisotropy (FA) fitting residuals were used to quantitatively assess the quality of spiral diffusion data for tensor estimation. Finally, the SNR performances and g‐factor behavior of the three spiral samplings were evaluated using a Monte Carlo‐based pseudo multiple replica method.
Results
Among the three spiral trajectories with the same readout duration, UDS sampling exhibited the least off‐resonance artifacts. This was most evident when the static B0 off‐resonance effect was severe. The UDS diffusion images had higher anatomical fidelity and lower FA fitting residuals than the other two counterparts. Furthermore, the four‐shot UDS acquisition achieved the best SNR performance in diffusion imaging with 12.11% and 40.85% improvements over the VDS and DDS acquisitions with the same readout duration, respectively.
Conclusion
UDS sampling is an efficient spiral acquisition scheme for high‐resolution diffusion imaging with reliable navigator information. It provides superior off‐resonance performance and SNR efficiency over the VDS and DDS samplings for the tested scenarios.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China.
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.
- Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands.
- Philips Research, Hamburg, Germany.
- Center for MR Research and Departments of Radiology, Neurosurgery, and Biomedical Engineering, University of Illinois College of Medicine at Chicago, Chicago, Illinois, USA.
ORCID profiles: Xiaodong Ma, Sisi Li, Hua Guo
Funding
- Natural Science Foundation of Beijing Municipality
- National Natural Science Foundation of China
Cite
APA
Li, G., Ma, X., Li, S., Ye, X., Börnert, P., Zhou, X. J., & Guo, H. (2023). Comparison of uniform‐density, variable‐density, and dual‐density spiral samplings for multi‐shot DWI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29633
Vancouver
Li G, Ma X, Li S, Ye X, Börnert P, Zhou XJ, et al. Comparison of uniform‐density, variable‐density, and dual‐density spiral samplings for multi‐shot DWI. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29633
BibTeX
@article{Li2023,
author = {Li, Guangqi and Ma, Xiaodong and Li, Sisi and Ye, Xinyu and Börnert, Peter and Zhou, Xiaohong Joe and Guo, Hua},
title = {Comparison of uniform‐density, variable‐density, and dual‐density spiral samplings for multi‐shot DWI},
journal = {Magnetic Resonance in Medicine},
year = {2023},
doi = {10.1002/mrm.29633}
}
EUVIMED