Journal article in Magnetic Resonance in Medicine, 2023. Written by Sang Hun Chung and 8 co-authors. Institution: Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA. Major MEDLINE topics: Cystic Fibrosis, Respiration Disorders. Cited 8 times so far (Crossref); 59 references. The full text is freely available in PubMed Central. Funded by: NHLBI NIH HHS, NIDDK NIH HHS, Cystic Fibrosis Foundation.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To explore the feasibility of measuring ventilation defect percentage (VDP) using 19 F MRI during free‐breathing wash‐in of fluorinated gas mixture with postacquisition denoising and to compare these results with those obtained through traditional Cartesian breath‐hold acquisitions.

Methods

Eight adults with cystic fibrosis and 5 healthy volunteers completed a single MR session on a Siemens 3T Prisma. 1 H Ultrashort‐TE MRI sequences were used for registration and masking, and ventilation images with 19 F MRI were obtained while the subjects breathed a normoxic mixture of 79% perfluoropropane and 21% oxygen (O 2 ). 19 F MRI was performed during breath holds and while free breathing with one overlapping spiral scan at breath hold for VDP value comparison. The 19 F spiral data were denoised using a low‐rank matrix recovery approach.

Results

VDP measured using 19 F VIBE and 19 F spiral images were highly correlated ( r = 0.84) at 10 wash‐in breaths. Second‐breath VDPs were also highly correlated ( r = 0.88). Denoising greatly increased SNR (pre‐denoising spiral SNR, 2.46 ± 0.21; post‐denoising spiral SNR, 33.91 ± 6.12; and breath‐hold SNR, 17.52 ± 2.08).

Conclusion

Free‐breathing 19 F lung MRI VDP analysis was feasible and highly correlated with breath‐hold measurements. Free‐breathing methods are expected to increase patient comfort and extend ventilation MRI use to patients who are unable to perform breath holds, including younger subjects and those with more severe lung disease.

Subjects

MeSH terms (MEDLINE)

Cystic FibrosisRespiration DisordersAdultHumansHealthy VolunteersFeasibility StudiesRespirationLungMagnetic Resonance ImagingOxygen

Author keywords

19FVDPcystic fibrosisfree breathinglung MRI

Substances

Oxygen

Authors and institutions

  • Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
  • Division of Pulmonary and Critical Care Medicine, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
  • Marsico Lung Institute/UNC Cystic Fibrosis Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
  • Division of Pediatric Pulmonology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
  • Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA.
  • Department of Radiology and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.

ORCID profiles: Sang Hun Chung, Yueh Z Lee

Funding

  • NHLBI NIH HHS
  • NIDDK NIH HHS
  • Cystic Fibrosis Foundation
  • Korea National Institute of Health

Cite

APA

Chung, S. H., Huynh, K. M., Goralski, J. L., Chen, Y., Yap, P. T., Ceppe, A. S., Powell, M. Z., Donaldson, S. H., & Lee, Y. Z. (2023). Feasibility of free‐breathing 19 F MRI image acquisition to characterize ventilation defects in CF and healthy volunteers at wash‐in. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29630

Vancouver

Chung SH, Huynh KM, Goralski JL, Chen Y, Yap PT, Ceppe AS, et al. Feasibility of free‐breathing 19 F MRI image acquisition to characterize ventilation defects in CF and healthy volunteers at wash‐in. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29630

BibTeX
@article{Chung2023,
  author = {Chung, Sang Hun and Huynh, Khoi Minh and Goralski, Jennifer L and Chen, Yong and Yap, Pew-Thian and Ceppe, Agathe S and Powell, Margret Z and Donaldson, Scott H and Lee, Yueh Z},
  title = {Feasibility of free‐breathing 19 F MRI image acquisition to characterize ventilation defects in CF and healthy volunteers at wash‐in},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29630}
}
Start for free →