EUVIMEDEUVIMED entdecken
VergleichsstudieValidierungsstudieOpen Access · CC BY 4.0

Sequence comparison of spoiled gradient echo and balanced steady‐state free precession for pulmonary free‐breathing proton MRI in patients and healthy volunteers: Correspondence, repeatability, and validation with dynamic contrast‐enhanced MRI

Jonah J Hahn, Andreas Voskrebenzev, Lea Behrendt, Filip Klimeš iD, Gesa H Pöhler, Frank Wacker, Jens Vogel-Claussen

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5209 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Jonah J Hahn und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hanover, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Respiration, Contrast Media, Lung. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Else Kröner-Fresenius-Stiftung, Siemens Healthineers.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Phase‐resolved functional lung (PREFUL) MRI is a proton‐based, contrast agent‐free technique derived from the Fourier decomposition approach to measure regional ventilation and perfusion dynamics during free‐breathing. Besides the necessity of extensive PREFUL postprocessing, the utilized MRI sequence must fulfill specific requirements. This study investigates the impact of sequence selection on PREFUL‐MRI–derived functional parameters by comparing the standard spoiled gradient echo (SPGRE) sequence with a lung‐optimized balanced steady‐state free precession (bSSFP) sequence, thereby facilitating PREFULs clinical application in pulmonary disease assessment. This study comprised a prospective dataset of healthy volunteers and a retrospective dataset of patients with suspected chronic thromboembolic pulmonary hypertension. Both cohorts underwent PREFUL‐MRI with both sequences to assess the correspondence of PREFUL ventilation and perfusion parameters (A). Additionally, healthy subjects were scanned a second time to evaluate repeatability (B), whereas patients received dynamic contrast‐enhanced (DCE)‐MRI, considered the perfusion gold standard for comparison with PREFUL‐MRI (C). Signal‐to‐noise ratio (SNR), calculated from the unprocessed images, was compared alongside median differences of PREFUL‐MRI–derived parameters using a paired Wilcoxon signed rank test. Further evaluations included calculation of the Pearson correlation, intraclass‐correlation coefficient for repeatability assessment, and spatial overlap (SO) for regional comparison of PREFUL‐MRI and DCE‐MRI. bSSFP showed a clear SNR advantage over SPGRE (median: 23 vs. 9, p < 0.001). (A) Despite significant differences, parameter values were strongly correlated (r ≥ 0.75). After thresholding, binary maps showed high healthy overlap across both cohorts (SO Healthy > 86%) and high defect overlap in the patient cohort (SO Defect ≥ 48%). (B) bSSFP demonstrated slightly higher repeatability across most parameters. (C) Both sequences demonstrated comparable correspondence to DCE‐MRI, with SPGRE excelling in absolute quantification and bSSFP in spatial agreement. Although bSSFP showed superior SNR results, both sequences displayed spatial defect concordance and highly correlated PREFUL parameters with deviations regarding repeatability and alignment with DCE‐MRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingRespirationContrast MediaLungHealthy VolunteersHumansMaleFemaleMiddle AgedAdultReproducibility of ResultsProtonsAgedSignal-To-Noise Ratio

Stichwörter der Autor:innen

Fourier decompositionPREFULSPGREbSSFPfree‐breathing V/Qlung MRI

Substanzen

Contrast MediaProtons

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hanover, Germany.
  • Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), Member of the German Center for Lung Research (DZL), Hanover, Germany.

ORCID-Profile: Filip Klimeš

Förderung

  • Else Kröner-Fresenius-Stiftung
  • Siemens Healthineers

Zitieren

APA

Hahn, J. J., Voskrebenzev, A., Behrendt, L., Klimeš, F., Pöhler, G. H., Wacker, F., & Vogel-Claussen, J. (2024). Sequence comparison of spoiled gradient echo and balanced steady‐state free precession for pulmonary free‐breathing proton MRI in patients and healthy volunteers: Correspondence, repeatability, and validation with dynamic contrast‐enhanced MRI. NMR in Biomedicine. https://doi.org/10.1002/nbm.5209

Vancouver

Hahn JJ, Voskrebenzev A, Behrendt L, Klimeš F, Pöhler GH, Wacker F, et al. Sequence comparison of spoiled gradient echo and balanced steady‐state free precession for pulmonary free‐breathing proton MRI in patients and healthy volunteers: Correspondence, repeatability, and validation with dynamic contrast‐enhanced MRI. NMR in Biomedicine. 2024. doi:10.1002/nbm.5209

BibTeX
@article{Hahn2024,
  author = {Hahn, Jonah J and Voskrebenzev, Andreas and Behrendt, Lea and Klimeš, Filip and Pöhler, Gesa H and Wacker, Frank and Vogel-Claussen, Jens},
  title = {Sequence comparison of spoiled gradient echo and balanced steady‐state free precession for pulmonary free‐breathing proton MRI in patients and healthy volunteers: Correspondence, repeatability, and validation with dynamic contrast‐enhanced MRI},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5209}
}
Kostenlos starten →