Quantitative SPECT imaging of 225 Ac and its daughters in mice in vivo
Medical Physics · 2026
DOI: 10.1002/mp.70674 ↗At a glance
Journal article in Medical Physics, 2026. Written by Shixian Du and 6 co-authors. Institution: Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA. Major MEDLINE topics: Actinium, Single Photon Emission Computed Tomography Computed Tomography, Tomography, Emission-Computed, Single-Photon. 20 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIH HHS, NIBIB NIH HHS, NCI NIH HHS.
Abstract (original language)
Background
Targeted alpha therapy (TAT) using actinium‐225 ( 225 Ac) holds great promise for cancer treatment, and to advance 225 Ac therapy it is required to develop accurate dosimetry method. 225 Ac daughters, especially 213 Bi, may redistribute and cause renal toxicity. Currently, direct imaging of 225 Ac‐emitted photons at low injected activity levels remains a technical challenge for image‐based 225 Ac dosimetry.
Purpose
This study aims to assess the feasibility and accuracy of quantitative in vivo SPECT/CT imaging for 225 Ac and its decay daughters at activity levels similar to those in small animal studies.
Methods
A state‐of‐the‐art commercial preclinical SPECT/CT scanner was used to image healthy nude mice in vivo and ex vivo after injection of unlabeled 225 Ac from the United States Department of Energy isotope program, at activities below 48.8 kBq. Each in‐vivo imaging was 1.5 h and ex‐vivo imaging was 12 h, at approximately 2 h after injection of 225 Ac, and all SPECT images were reconstructed at multi‐energy windows (82, 218, and 440 keV). Mouse‐like phantom imaging for 1 h at 0.078 MBq and 12 h at 0.496 MBq were also performed to validate quantitative accuracy.
Results
In vivo SPECT/CT images clearly showed abundant liver uptake, and significant kidney uptake was also observed in 440 keV images for 213 Bi, consistent with known renal toxicity from daughter redistribution. However, quantitative analysis of in vivo, ex vivo, and low‐activity phantom images revealed suboptimal quantitative accuracy, with high background recovery coefficients and variations in measured activity across the energy windows.
Conclusions
We demonstrated the ability to image 225 Ac and its daughters in vivo at low activity levels. However, the quantitative results confirmed that, even with the state‐of‐the‐art preclinical SPECT/CT system, current methods and reconstruction algorithms may not provide sufficient accuracy for accurate dosimetry at typical activity used in small animal studies.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
- Department of Nuclear Engineering, University of California, Berkeley, California, USA.
- Department of Nuclear Engineering, University of Tennessee-Knoxville, Knoxville, Tennessee, USA.
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, California, USA.
- Department of Pharmaceutical Chemistry, University of California, San Francisco, California, USA.
Funding
- NIH HHS
- NIBIB NIH HHS
- NCI NIH HHS
- DOD
- National Institutes of Health
- U.S. Department of Defense
Cite
APA
Du, S., Bobba, K. N., Peter, R., Gullberg, G. T., Flavell, R. R., Caravaca, J., & Seo, Y. (2026). Quantitative SPECT imaging of 225 Ac and its daughters in mice in vivo. Medical Physics. https://doi.org/10.1002/mp.70674
Vancouver
Du S, Bobba KN, Peter R, Gullberg GT, Flavell RR, Caravaca J, et al. Quantitative SPECT imaging of 225 Ac and its daughters in mice in vivo. Medical Physics. 2026. doi:10.1002/mp.70674
BibTeX
@article{Du2026,
author = {Du, Shixian and Bobba, Kondapa Naidu and Peter, Robin and Gullberg, Grant T and Flavell, Robert R and Caravaca, Javier and Seo, Youngho},
title = {Quantitative SPECT imaging of 225 Ac and its daughters in mice in vivo},
journal = {Medical Physics},
year = {2026},
doi = {10.1002/mp.70674}
}
EUVIMED