Investigation of the Optimal Parameters for Block Sequential Regularized Expectation Maximization (BSREM) Reconstruction in Bone SPECT Using a Ring-type Semiconductor SPECT/CT
Japanese Journal of Radiological Technology · 2025
DOI: 10.6009/jjrt.25-1560 ↗Kurz gefasst
Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2025. Verfasst von Hayato Sato und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine. Hauptthemen laut MEDLINE: Tomography, Emission-Computed, Single-Photon, Bone and Bones, Image Processing, Computer-Assisted, Single Photon Emission Computed Tomography Computed Tomography. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This research aims to optimize the block sequential regularized expectation maximization (BSREM) reconstruction in bone single photon emission computed tomography (SPECT) images using a ring-type SPECT/computed tomography (CT) system in terms of image quality and accuracy of quantitative evaluation. METHODS: SPECT images were acquired using a ring-type SPECT/CT and from a SIM2 bone phantom containing a 99m-Tc solution. BSREM parameters were assessed with coefficient of variation (CV), recovery coefficient (RC), contrast noise ratio (CNR), standardized uptake value max (SUVmax), and its root mean square error (RMSESUVmax). Clinical images were reconstructed, and the reconstructions were evaluated as superior based on phantom results. RESULTS: Increasing γ led to higher RC and CV, while increasing β lowered these values. CNR showed no consistent trend. In terms of quantitative evaluation, γ value 5.0, β values 0.3-0.9, and γ value 10, βvalues 0.3-0.9 resulted in lower RMSESUVmax compared to Anger type. Based on the phantom experiment, γ value 5.0, β values 0.5-0.9, and γ value 10, β values 0.7-0.9 were evaluated as superior. Clinical images under these reconstructions, determined from the phantom experiments, with γ value 5.0, β value 0.9, showed the smoothest of normal bone and the clearest separation of neighboring tumors. CONCLUSION: As reconstruction parameters for BSREM reconstruction in bone SPECT on a ring-type semiconductor SPECT/CT system, a γ value of 5.0 and a β value of 0.9 were considered suitable for image quality and quantitative evaluation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine.
- Department of Diagnostic Radiology, Tohoku University Hospital.
- Department of Radiological Technology, Tohoku University Hospital.
Zitieren
APA
Sato, H., Odagiri, H., Yamaguchi, N., Kodama, H., Takeuchi, T., Tanaka, Y., Takanami, K., Usui, A., & Kaneta, T. (2025). Investigation of the Optimal Parameters for Block Sequential Regularized Expectation Maximization (BSREM) Reconstruction in Bone SPECT Using a Ring-type Semiconductor SPECT/CT. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.25-1560
Vancouver
Sato H, Odagiri H, Yamaguchi N, Kodama H, Takeuchi T, Tanaka Y, et al. Investigation of the Optimal Parameters for Block Sequential Regularized Expectation Maximization (BSREM) Reconstruction in Bone SPECT Using a Ring-type Semiconductor SPECT/CT. Japanese Journal of Radiological Technology. 2025. doi:10.6009/jjrt.25-1560
BibTeX
@article{Sato2025,
author = {Sato, Hayato and Odagiri, Hayato and Yamaguchi, Nao and Kodama, Hiroyasu and Takeuchi, Takashi and Tanaka, Yoshitaka and Takanami, Kentaro and Usui, Akihito and Kaneta, Tomohiro},
title = {Investigation of the Optimal Parameters for Block Sequential Regularized Expectation Maximization (BSREM) Reconstruction in Bone SPECT Using a Ring-type Semiconductor SPECT/CT},
journal = {Japanese Journal of Radiological Technology},
year = {2025},
doi = {10.6009/jjrt.25-1560}
}
EUVIMED