EUVIMEDEUVIMED entdecken
Crossref

Optimization of Block Sequential Regularized Expectation Maximization Reconstruction Parameters for Striatal SPECT Using a Ring-Type Semiconductor SPECT/CT System

Nao Yamaguchi, Hayato Odagiri, Hayato Sato, Hiroyasu Kodama, Yoshitaka Tanaka, Takashi Takeuchi, Kentaro Takanami, Akihito Usui, Tomohiro Kaneta

Journal of Nuclear Medicine Technology · 2026

DOI: 10.2967/jnmt.125.269869 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine Technology, 2026. Verfasst von Nao Yamaguchi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine, Miyagi, Japan. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Single Photon Emission Computed Tomography Computed Tomography, Semiconductors, Tomography, Emission-Computed, Single-Photon. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This phantom study aimed to optimize the noise-suppression parameter (β) and the edge-preservation parameter (γ) values in the block sequential regularized expectation maximization (BSREM) reconstruction method for 123I-2-β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)nortropane striatal SPECT using a ring-type cadmium-zinc-telluride camera.

Methods

We used a striatum phantom filled with an 123I solution, with adjusted concentrations in the left and right caudate and left and right putamen. The phantom was scanned for 120 min using the StarGuide system, and 20-min SPECT data were extracted from the total acquisition. Using the BSREM method, we generated 42 reconstructed images by varying β and γ. We calculated the percent coefficient of variation and percent contrast for each image. Visual evaluations were conducted by a nuclear medicine physician and 2 technologists. Additionally, we calculated the striatal uptake ratio (SUR) and the ratio of the left caudate SUR to putamen SUR in the left striatum (left striatal ratio).

Results

The percent coefficient of variation decreased as the β value increased, whereas percent contrast increased as the γ value increased. We conducted a visual evaluation of 15 reconstructed images selected by physical assessment. Images reconstructed with a β value of 0.03 with a γ value of 5 and those with a β value of 0.05 with a γ value of 10 were deemed suitable for diagnostic purposes because of their accurate depiction of tracer accumulation in each striatal region. SUR and left striatal ratio were comparable for these 2 image sets.

Conclusion

Evaluation of the optimal conditions for striatal SPECT imaging with BSREM reconstruction revealed that the optimal β value and γ value combinations were a β value of 0.03 and γ value of 5 and a β value of 0.05 and γ value of 10.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedSingle Photon Emission Computed Tomography Computed TomographySemiconductorsTomography, Emission-Computed, Single-PhotonNeostriatumPhantoms, ImagingHumans

Stichwörter der Autor:innen

123I-FP-CITSPECT/CT imagingblock sequential regularized expectation maximization methodring-type semiconductor SPECT/CT systemstriatal uptake ratio

Autor:innen und Institutionen

  • Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine, Miyagi, Japan.
  • Department of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine, Miyagi, Japan; hayato.odagirie2@tohoku.ac.jp.
  • Department of Diagnostic Radiology, Tohoku University Hospital, Miyagi, Japan; and.
  • Department of Radiological Technology, Tohoku University Hospital, Miyagi, Japan.

Zitieren

APA

Yamaguchi, N., Odagiri, H., Sato, H., Kodama, H., Tanaka, Y., Takeuchi, T., Takanami, K., Usui, A., & Kaneta, T. (2026). Optimization of Block Sequential Regularized Expectation Maximization Reconstruction Parameters for Striatal SPECT Using a Ring-Type Semiconductor SPECT/CT System. Journal of Nuclear Medicine Technology. https://doi.org/10.2967/jnmt.125.269869

Vancouver

Yamaguchi N, Odagiri H, Sato H, Kodama H, Tanaka Y, Takeuchi T, et al. Optimization of Block Sequential Regularized Expectation Maximization Reconstruction Parameters for Striatal SPECT Using a Ring-Type Semiconductor SPECT/CT System. Journal of Nuclear Medicine Technology. 2026. doi:10.2967/jnmt.125.269869

BibTeX
@article{Yamaguchi2026,
  author = {Yamaguchi, Nao and Odagiri, Hayato and Sato, Hayato and Kodama, Hiroyasu and Tanaka, Yoshitaka and Takeuchi, Takashi and Takanami, Kentaro and Usui, Akihito and Kaneta, Tomohiro},
  title = {Optimization of Block Sequential Regularized Expectation Maximization Reconstruction Parameters for Striatal SPECT Using a Ring-Type Semiconductor SPECT/CT System},
  journal = {Journal of Nuclear Medicine Technology},
  year = {2026},
  doi = {10.2967/jnmt.125.269869}
}
Kostenlos starten →